Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1534806.1
Update Date:2017-03-22
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1534806.1 :   M10-device.misconfig_psu - An incorrect PSU was detected in a box  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
SPARC

Purpose

Provide additional information for message ID: M10-device.misconfig_psu

Fujitsu fault code:

018AF023

Details

Type

Hardware Fault
   device.misconfig_psu

Severity

Major

Description

A fault occurred when an incorrect PSU was detected.

Automated Response

The powerup request is rejected.

Impact

The server or XB-Box is deconfigured.

Indicted Hardware

The PSU is marked for replacement. It is possible that an unsupported (unknown) PSU is mounted. The part number of the indicted PSU should be obtained and compared to the Fujitsu FRU inventory for the particular server or XB-Box in question.

Suggested Action for System Administrator

The indicted PSU should be removed from the server or XB-Box. It is possible the server or XB-Box will power up once the indicted PSU is removed.