Solution Type  Predictive Self-Healing Sure

Solution  1537479.1 :   M10-io.pciex.pcibox.fe - Fatal error detected on a linkcard in a PCI slot or a linkbrd in a PCI expansion box  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10 PCI Expansion Unit
Fujitsu M10-1
Fujitsu M10-4S
Fujitsu M10-4
SPARC

Purpose

Provide additional information for message ID: M10-io.pciex.pcibox.fe

Fujitsu fault codes:

11000040, 11000042, 11000061, 11000062

Details

Type

Hardware Fault
   io.pciex.pcibox.fe

Severity

Major

Description

Fault due to a fatal error detected on a link card in a PCI slot or a link board in a PCI expansion box.

The detected fault is listed in the following categories:

- fe-linkcard-linkup-err: 11000040 The PCIe linkup process failed at a link card;

- fe-linkup-disconnect-err: 11000042 The link disconnect that occurs during the PCI expansion box firmware linkup process failed.

- fe-linkbrd-linkup-err: 11000061 The PCIe linkup process failed at a link board;

- se-linkcard-lane-degraded: 11000062 The link board detects the PCIe lane has been degraded and is operating at reduced speed.

In all cases, a domain cannot access to the PCI expansion box.

Automated Response

No immediate action is taken.

Impact

Nothing is deconfigured.

Indicted Hardware

First suspect is the link card, second suspect is a link cable between the linkcard and the PCI expansion box, and the third suspect is the link board on the PCI expansion box.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.