Solution Type  Predictive Self-Healing Sure

Solution  1536589.1 :   M10-if.ce-xb-xbucable - Permanent correctable errors detected at a cable connecting two XB chips  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-if.ce-xb-xbucable

Fujitsu fault codes:

0506301b, 05063136, 05063137, 0506320c, 05063220, 05063221

Details

Type

Hardware Fault
   if.ce-xb-xbucable

Severity

Major

Description

Fault due to a permanent correctable error detected at a cable connecting two XB chips.

When Building Blocks are connected by cables only, these XB chips are on XBUQ.

When Building Blocks are connected by XB-Box, one XB chip is on XBUQ, and the other XB chip is on XBUX in XB-Box.

Automated Response

No immediate action will be taken.

Impact

An XB-way is deconfigured when all the PPARs using the faulty XB chip are stopped.

Indicted Hardware

The XB cable is the first suspect, the XBUQ is the second suspect, and a FRU, where the other XB chip is mounted, is the third suspect.

When Building Blocks are directly connected by cables, then this third suspect is other Building Block.

When Building Blocks are connected via XB-Box, then this third suspect is a XB-Box.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.