Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1539401.1
Update Date:2016-01-04
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1539401.1 :   M10-upset_config.linkcable_pcibox_linkbrd_linkcable - An upset occurred during powerup  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-upset_config.linkcable_pcibox_linkbrd_linkcable

Fujitsu fault code:

1100003F

Details

Type

Hardware Fault
   upset_config.linkcable_pcibox_linkbrd_linkcable

Severity

Major

Description

PCI Expansion Unit firmware found that the PCI Expansion Unit is incorrectly connected to two link cards. A PCI Expansion Unit can only connect to one link card in a server.

Automated Response

No immediate action is taken.

Impact

Nothing is deconfigured.

Indicted Hardware

The link cable is specified as faulty.

Suggested Action for System Administrator

Check the pair of link cables between the PCI Expansion Unit and server link cards to ensure they are connected to the same link card.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.