Solution Type  Predictive Self-Healing Sure

Solution  1537490.1 :   M10-io.pciex.pcibox.se_iob - Error detected on an IOB in a PCI expansion box  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-1
Fujitsu M10-4S
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
SPARC

Purpose

Provide additional information for message ID: M10-io.pciex.pcibox.se_iob

Fujitsu fault code:

1100005C

Details

Type

Hardware Fault
   io.pciex.pcibox.se_iob

Severity

Major

Description

Fault due to a serious error detected on an IOB in a PCI expansion box.

Automated Response

The box is powered down.

Impact

Nothing is deconfigured. The IOB is marked to be deconfigured. When a domain requests to re-start the PCI expansion box, this PCI expansion box will not start.

Indicted Hardware

IOB is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.