Asset ID: |
1-79-1537511.1 |
Update Date: | 2017-03-21 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1537511.1
:
M10-i2c.device_pcibox_linkbrd - I2C access failure to I2C devices on an link board in a PCI expansion box
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
Fujitsu M10-4
Fujitsu M10-1
Fujitsu M10 PCI Expansion Unit
SPARC
Purpose
Provide additional information for message ID: M10-i2c.device_pcibox_linkbrd
1100004E, 11000053
Details
Type
- Hardware Fault
- i2c.device_pcibox_linkbrd
Severity
- Major
Description
-
Fault due to I2C access failure to I2C devices on an link board in a PCI expansion box.
The devices that are accessible are:
- sensors:
- LED controllers;
- controllers:
- I2C switches;
- seeprom:
- FRUID SEEPROMs.
These devices can no longer be accessed or controlled by the PCI expansion box firmware.
Automated Response
- No immediate action is taken.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The link board in the PCI expansion box is specified as faulty.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments