Asset ID: |
1-79-1526724.1 |
Update Date: | 2015-12-31 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1526724.1
:
M10-memory.block.mirror.ue - A data compare error has been detected when memory is in mirror mode
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
SPARC
Purpose
Provide additional information for message ID: M10-memory.block.mirror.ue
Fujitsu fault codes:
05030200, 05030201, 05030202, 05030203, 05030204, 05030205
Details
Type
- Hardware Fault
- memory.block.mirror.ue
Severity
- Critical
Description
-
Fault due to a data compare error when memory is in mirror mode, detected by the CPU chip hardware.
Automated Response
- No immediate action is taken by XSCF. It is expected that the domain will take appropriate action.
Impact
-
The DIMMs forming the mirroring pair where the compare error is detected are deconfigured (8 DIMMs total) after the domain using the affected memory reboots. The domain will get a memory uncorrectable error (UE) trap.
Indicted Hardware
- For M10-4/4S systems, the CMUU or CMUL is marked for replacement. For M10-1 systems, the MBU is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment