Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1537486.1
Update Date:2015-12-31
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1537486.1 :   M10-io.pciex.pcibox.fe_slot - Fatal error detected on a PCI Express slot in a PCI expansion box  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-io.pciex.pcibox.fe_slot

Fujitsu fault code:

11000064

Details

Type

Hardware Fault
   io.pciex.pcibox.fe_slot

Severity

Major

Description

Fault due to a fatal error detected on a PCI Express slot in a PCI expansion box.

PCI expansion box firmware detects that the PCI Express linkup process at the PCI slot has failed.

Automated Response

No immediate action is taken. Solaris may panic or FMA running on Solaris will take appropriate action. If the domain does stay up, the domain does not require immediate attention.

The platform administrator should ensure the domain does not use the PCI Express card for an extended period of time. The platform administrator should also schedule a service action.

Impact

Nothing is deconfigured by XSCF or PCI expansion box firmware. FMA running on Solaris may take appropriate action.

Indicted Hardware

The PCI Express card is the first suspect. There is small chance that the problem is actually in the IOB.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)