Asset ID: |
1-79-1534809.1 |
Update Date: | 2015-12-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1534809.1
:
M10-device.missing_psubp_ddc - A DDC on a PSUBP in M10-1, M10-4 or M10-4S is missing or could not be detected
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S Fujitsu M10-1 Fujitsu M10-4 SPARC
Purpose
Provide additional information for message ID: M10-device.missing_psubp_ddc
Fujitsu fault code:
018AF050
Details
Type
- Hardware Fault
- device.missing_psubp_ddc
Severity
- Major
Description
-
A fault occurred during powerup where a DDC on a PSUBP in M10-1, M10-4 or M10-4S is missing or could not be detected.
Automated Response
- For M10-1 or M10-4 servers, the platform is powered down.
For M10-4S servers, no immediate action will be taken, because the PPar continues power-on sequence with this building block deconfigured.
Impact
- For M10-1 or M10-4 servers, the platform becomes unbootable.
For M10-4S servers, the building block becomes unbootable.
Indicted Hardware
- The PSUBP is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment
|