Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1536605.1
Update Date:2015-12-30
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1536605.1 :   M10-if.fe-asic-clk_xbu_xb - Fatal clock distribution error detected by a XB chip  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-if.fe-asic-clk_xbu_xb

Fujitsu fault codes:

05067000, 05067001

Details

Type

Hardware Fault
   if.fe-asic-clk_xbu_xb

Severity

Major

Description

Fault due to a fatal clock distribution error detected by a XB chip.

Automated Response

PPARs using this XB chip are reset.

Impact

The XBU is deconfigured.

An XB-way is deconfigured on PPARs that are using this XB chip.

Indicted Hardware

XBU, where this XB chip is mounted, is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback