Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1526593.1
Update Date:2015-12-30
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1526593.1 :   M10-cpu.core.se-offlinereq - Too many CPU serious faults, such as 05012700, have occurred  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-cpu.core.se-offlinereq

Fujitsu fault codes:

05012500, 05012501, 05012502, 05012503, 05012504, 05012505

Details

Type

Hardware Fault
   cpu.core.se-offlinereq

Severity

Major

Description

Fault that indicates too many CPU serious faults, such as 05012700, have occurred.

Automated Response

No immediate action is taken. The affected CPU may take a UE trap, enter RED state or encounter a data UE. If the domain does not panic then the domain subscribes to this fault and the domain software will attempt to offline the core. If this is a UE in the (shared) L2$, then each of the cores is separately indicted. The administrator should ensure that the affected CPU is removed from the domain configuration.

Impact

The core of the CPU chip is deconfigured the next time the domain reboots.

Indicted Hardware

For M10-1 systems the Motherboard is marked for replacement. For M10-4 and M10-4S systems, the related Motherboard (CMUU or CMUL) is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment