Asset ID: |
1-79-1526593.1 |
Update Date: | 2015-12-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1526593.1
:
M10-cpu.core.se-offlinereq - Too many CPU serious faults, such as 05012700, have occurred
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10-4S
SPARC
Purpose
Provide additional information for message ID: M10-cpu.core.se-offlinereq
Fujitsu fault codes:
05012500, 05012501, 05012502, 05012503, 05012504, 05012505
Details
Type
- Hardware Fault
- cpu.core.se-offlinereq
Severity
- Major
Description
-
Fault that indicates too many CPU serious faults, such as 05012700, have occurred.
Automated Response
- No immediate action is taken. The affected CPU may take a UE trap, enter RED state or encounter a data UE. If the domain does not panic then the domain subscribes to this fault and the domain software will attempt to offline the core. If this is a UE in the (shared) L2$, then each of the cores is separately indicted. The administrator should ensure that the affected CPU is removed from the domain configuration.
Impact
-
The core of the CPU chip is deconfigured the next time the domain reboots.
Indicted Hardware
- For M10-1 systems the Motherboard is marked for replacement. For M10-4 and M10-4S systems, the related Motherboard (CMUU or CMUL) is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)