Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1534882.1
Update Date:2016-01-06
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1534882.1 :   M10-env.power.loss - A power supply (PSU) detected a loss of AC power  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10 PCI Expansion Unit
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
SPARC

Purpose

Provide additional information for message ID: M10-env.power.loss

Fujitsu fault codes:

11000029, 1100002A

Details

Type

Hardware Fault
   env.power.loss

Severity

Major

Description

A fault occurred due to a PSU detecting a loss of input AC power.

Automated Response

If there are insufficient operational PSUs, then the box is powered down. Otherwise, no action is taken.

The platform administrator should check the AC power connections and schedule a service action if necessary.

Impact

Nothing is deconfigured.

Indicted Hardware

The suspect is the external environment, but the PSU is displayed to show which supply detected the external fault.

Suggested Action for System Administrator

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment