Asset ID: |
1-79-1534882.1 |
Update Date: | 2016-01-06 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1534882.1
:
M10-env.power.loss - A power supply (PSU) detected a loss of AC power
Related Items |
- Fujitsu M10-4
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10 PCI Expansion Unit
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
SPARC
Purpose
Provide additional information for message ID: M10-env.power.loss
Fujitsu fault codes:
11000029, 1100002A
Details
Type
- Hardware Fault
- env.power.loss
Severity
- Major
Description
-
A fault occurred due to a PSU detecting a loss of input AC power.
Automated Response
- If there are insufficient operational PSUs, then the box is powered down. Otherwise, no action is taken.
The platform administrator should check the AC power connections and schedule a service action if necessary.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The suspect is the external environment, but the PSU is displayed to show which supply detected the external fault.
Suggested Action for System Administrator
- Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment