Solution Type  Predictive Self-Healing Sure

Solution  1537309.1 :   M10-mbc.ce - Persistent correctable errors detected by an MBC chip within itself  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
SPARC

Purpose

Provide additional information for message ID: M10-mbc.ce

Fujitsu fault codes:

05071400, 05071401, 05071500, 05071501

Details

Type

Hardware Fault
   mbc.ce

Severity

Major

Description

Fault due to persistent correctable errors detected by an MBC chip within itself, on the SRAM that is used for communication between a domain and an XSCF, or on the flash memory, where POST, OBP and HV program image is stored.

This fault can occur on an MBC on a Motherboard (MBU for M10-1, CMUL for M10-4/4S).

Automated Response

No immediate action is taken by XSCF software due to this fault.

However, the platform administrator should schedule a service action.

Impact

For M10-1 and M10-4 systems, the platform becomes unbootable.

For M10-4S, this building block is deconfigured.

Indicted Hardware

For M10-1 systems, MBU is marked for replacement.

For M10-4 or M10-4S systems, CMUL is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.