Solution Type  Predictive Self-Healing Sure

Solution  1933615.1 :   M10-device.fan.tooslow@pcibox - The rotation speed of a PCI Expansion Box fan (including fans in fan trays or in PSUs) is incorrect  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-1
Fujitsu M10-4S
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
SPARC

Purpose

Provide additional information for message ID: M10-device.fan.tooslow@pcibox

Fujitsu fault codes:

1100002E, 1100002F

Details

Type

Hardware Fault
   device.fan.tooslow@pcibox

Severity

Major

Description

Fault due to the rotation speed of a PCI Expansion Box fan (including fans in fan trays or in PSUs) being either lower than its predefined threshold or a fan is stopped completely.

Automated Response

When a fan in a PSU in PCI expansion box is failed, then this PSU will be stopped.

Impact

For a PCI expansion box, if the failure is due to the fan in a PSU, then the PSU is deconfigured.

In all other cases, nothing is deconfigured.

Indicted Hardware

The fan, fan tray, or PSU is marked for replacement.

Once the full complement of fans has been restored (this includes the replacement of PSUs with faulty fans) for the box (and once the temperature for all temperature sensors is in normal range) the speed of all the fans is returned to normal speed.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)