Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2060087.1
Update Date:2016-01-05
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2060087.1 :   M10-4S XSCF can report a self diagnosis warning detection fault every 10 days  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: There is no actionable fault or message generated for this fault code (01e40001)

Fujitsu fault code:

01e40001

Details

Type

Hardware Warning
   No hardware fault is generated

Severity

Minor

Description

M10-4S with more than one Building Block (BB) configured may report an event with status=notice and message XSCF self diagnosis warning detection on one or more BBs, if the installed XSCF firmware version is lower than XCP2280.

Example 'showlogs error' output:

Date: Sep 15 10:42:38 HKT 2015
    Code: 20000000-00560300fcff0000ff-01e400010000000000000000
    Status: Notice                 Occurred: Sep 15 10:43:08.531 HKT 2015
    FRU: /BB#2/CMUL,/FIRMWARE
    Msg: XSCF self diagnosis warning detection
    Diagnostic Code:
        02000000 00000000 0000
        00000000 00000000 0000
        00000000 00000000 0000
        00000000 00000000 00000000 00000000
        00000000 00000000 0000

This fault is due to a firmware bug. See the archived Product Notes, reference RTIF2-140527-001.

Automated Response

No action is taken by the M10-4S XSCF.

Impact

None.

Indicted Hardware

 XSCF firmware and the CMUL will be indicted under FRU in the 'showlogs error' output, but this is not a hardware fault. Do not replace any parts.

Suggested Action for System Administrator

The recommended service action for this event is to upgrade the XSCFU firmware to version XCP2280 or later.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.