Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1534066.1
Update Date:2015-12-31
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1534066.1 :   M10-power.power-off_pcibox_iob_ddc - A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10 PCI Expansion Unit
SPARC

Purpose

Provide additional information for message ID: M10-power.power-off_pcibox_iob_ddc

Fujitsu fault codes:

11000016, 11000017, 11000018, 11000019, 1100001A, 1100001B

Details

Type

Hardware Fault
   power.power-off_pcibox_iob_ddc

Severity

Major

Description

A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB and the power-off failed.

Automated Response

No immediate action is taken because of this fault, and the poweroff sequence continues. The platform administrator should schedule a service action.

Impact

The IOB is deconfigured. This means the PCI expansion box is deconfigured.

Indicted Hardware

The IOB is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)