Asset ID: |
1-79-1534066.1 |
Update Date: | 2015-12-31 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1534066.1
:
M10-power.power-off_pcibox_iob_ddc - A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10 PCI Expansion Unit
SPARC
Purpose
Provide additional information for message ID: M10-power.power-off_pcibox_iob_ddc
Fujitsu fault codes:
11000016, 11000017, 11000018, 11000019, 1100001A, 1100001B
Details
Type
- Hardware Fault
- power.power-off_pcibox_iob_ddc
Severity
- Major
Description
-
A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB and the power-off failed.
Automated Response
- No immediate action is taken because of this fault, and the poweroff sequence continues. The platform administrator should schedule a service action.
Impact
- The IOB is deconfigured. This means the PCI expansion box is deconfigured.
Indicted Hardware
- The IOB is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment