M10-asic.power.fail - Power failure is detected on an ASIC
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S Fujitsu M10-4 Fujitsu M10-1 SPARC
Purpose
Provide additional information for message ID: M10-asic.power.fail
Fujitsu error codes:
01A70100, 01A70103, 01A70104, 01A70130, 01A70132, 01A70133, 01A70160, 01A70162, 01A70163, 01A70201, 01A70205, 01A70231, 01A70234, 01A70261, 01A70264, 01A70306, 01A70335, 01A70336, 01A70365, 01A70437, 01A70538, 01A7063a, 01A7063c, 01A7063d, 01A7063e, 01A7073b, 01A7073f
Details
Type
- Hardware Fault
- asic.power.fail
Severity
- Major
Description
-
A power failure is detected on an M10 server or XB-Box ASIC.
Automated Response
- If this is a power failure of a Motherboard on an M10-1 or M10-4 system, the entire platform is reset.
If this is the power failure of a Building Block on an M10-4S system, then the PPAR, which is using the the Building Block to form a PPAR, is reset. If this is a power failure of an XB-Box on a M10-4S system, then the PPARs, which are using the XB-Box to form a PPAR, is reset.
Impact
- Nothing is deconfigured. It is expected that another fault will identify the part to be deconfigured.
Indicted Hardware
- When this failure happened on M10-1, MBU is the suspect.
When this failure is detected on CMUU/CMUL on M10-4/4S, CMUL is the suspect. When this failure is detected on XBU on M10-4S, XBU is the first suspect, and CMUL is the second suspect. When this failure is detected on XBUX on XB-Box, XBUX is the first suspect. There is slight chance XBBPX is faulty. There are two types of faults that are detected: - A failure reading or writing an interrupt mask for a particular ASIC or CPU chip, due to a power failure the affects the ASIC or CPU chip. The- power failure will cause its own ereport/fault, and this fault just logs an additional symptom of the power failure.
-
The following types of chips can be identified at failure: - A CPU chip; - An XB chip - An MBC chip - A fatal error happens on an ASIC (a failure that would normally produce an fatal error, such as 05010000). However, when this fatal error- occurs the XSCF detects that a DDC failure has occurred, and thus produces a power failure event instead of a fatal error. For this type of
- fault, only the fact that the fault occurred is known (not even the type of ASIC that had the fatal error is identified).
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)