Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1594335.1
Update Date:2017-03-22
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1594335.1 :   M10-config.xbbox_xbbox_xbu - A fault occurred during powerup  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-config.xbbox_xbbox_xbu

Fujitsu fault codes:

018AF0E0, 018AF0E1, 018AF0E2

Details

Type

Hardware Fault
   config.xbbox_xbbox_xbu

Severity

Major

Description

A fault occurred during powerup of an XB-Box because the XB board(s) in the XB-Box was/were not detected.

Automated Response

No action is taken; the powerup proceeds normally without the failed XB board(s).

Impact

The failed XB board is deconfigured.

Indicted Hardware

The XB board is the suspect. There is a possiblity that the XB board is not inserted correctly.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback