Asset ID: |
1-79-1594335.1 |
Update Date: | 2017-03-22 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1594335.1
:
M10-config.xbbox_xbbox_xbu - A fault occurred during powerup
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
SPARC
Purpose
Provide additional information for message ID: M10-config.xbbox_xbbox_xbu
Fujitsu fault codes:
018AF0E0, 018AF0E1, 018AF0E2
Details
Type
- Hardware Fault
- config.xbbox_xbbox_xbu
Severity
- Major
Description
-
A fault occurred during powerup of an XB-Box because the XB board(s) in the XB-Box was/were not detected.
Automated Response
- No action is taken; the powerup proceeds normally without the failed XB board(s).
Impact
- The failed XB board is deconfigured.
Indicted Hardware
- The XB board is the suspect. There is a possiblity that the XB board is not inserted correctly.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment