Asset ID: |
1-79-1594351.1 |
Update Date: | 2015-12-31 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1594351.1
:
M10-upset_config_opnl - Operator Panel (OPNL) not detected during powerup
Related Items |
- Fujitsu M10-1
- Fujitsu M10-4S
- Fujitsu M10-4
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-1 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
SPARC
Purpose
Provide additional information for message ID: M10-upset_config_opnl
Fujitsu fault code:
018AF0F2
Details
Type
- Hardware Fault
- upset_config_opnl
Severity
- Minor
Description
-
An upset occurred during powerup (either at connecting power to a box or initial powerup of PPAR) because the Operator Panel was not detected.
Automated Response
- No action is taken; the powerup proceeds normally.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The Operator Panel is the suspect.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment