Asset ID: |
1-79-1537682.1 |
Update Date: | 2015-12-31 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1537682.1
:
M10-upset_config.fan_pcibox - The number of fans in a PCI expansion box are insufficient
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
SPARC
Purpose
Provide additional information for message ID: M10-upset_config.fan_pcibox
Fujitsu fault codes:
1100002C, 1100002D
Details
Type
- Hardware Fault
- upset_config.fan_pcibox
Severity
- Major
Description
-
An upset occurred during powerup where the number of fans in a PCI expansion box are insufficient.
Automated Response
- The PCI expansion box will not power up.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The fan is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment