Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1526710.1
Update Date:2015-12-31
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1526710.1 :   M10-memory.block.ue - DIMM uncorrectable error detected  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4
Fujitsu M10-1
Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-memory.block.ue

Fujitsu fault codes:

0200140a, 05032309, 05032000, 05032001, 05032002, 05032003,
05032005, 05032007, 0503200c, 0503200d, 0503200e, 0503200f, 05032010,
05032011, 05032015, 05032016, 05032017, 0503230a, 0503230b, 0503230f,
05032310, 05032311, 05032312, 05032313, 05032314, 05032315, 05032316,
05032317

Details

Type

Hardware Fault
   memory.block.ue

Severity

Critical

Description

Fault due to DIMM uncorrectable error detected by the MAC in a CPU chip.

Automated Response

No immediate action is taken by XSCF. It is expected that the domain will take appropriate action.

Impact

The DIMMs with the UE are marked for replacement. The 256MB memory chunk that contains the uncorrectable error is deconfigured after the physical partition reboots.

Indicted Hardware

If the memory is running in non-mirrored mode, then two DIMMs are actually involved in the UE. There will be a separate event for each of the DIMMs.

If the memory is running in mirrored mode, then four DIMMs are actually involved in a UE. There will be a separate event for each of the DIMMs.

For M10-1 systems, there is a slight chance the MBU is at fault, and this will be listed as the second suspect FRU.

For M10-4/4S systems, there is a slight chance the CMUU/CMUL is at fault, and this will be listed as the second suspect FRU.

It is also possible that one of the DIMMs involved in the UE is not seated correctly.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.