Purpose

Provide additional information for message IDs: M10-lrci

Fujitsu fault code:

07F70001

Details

Type

Hardware Fault
   lrci

Severity

Minor

Description

Fault due to an error that was detected by an LRCI supported device connected via LAN.

The types of faults that are detected are:

- an LRCI device is not responding and may be faulty;

- an LRCI device reported an error.

Automated Response

If the LRCI device is not responding, the system will continue to run, but there will be no communication with this LRCI device.

If the LRCI device reported an error, the information is logged, and no further action is taken.

Impact

Nothing is deconfigured.

Indicted Hardware

No FRU is specified. The error message contains the identity of LRCI device.

Suggested Action for System Administrator

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)