Asset ID: |
1-79-1537478.1 |
Update Date: | 2017-03-21 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1537478.1
:
M10-lrci - An error was detected by an LRCI supported device connected via LAN
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
SPARC
Purpose
Provide additional information for message IDs: M10-lrci
Fujitsu fault code:
07F70001
Details
Type
- Hardware Fault
- lrci
Severity
- Minor
Description
-
Fault due to an error that was detected by an LRCI supported device connected via LAN.
The types of faults that are detected are:
- an LRCI device is not responding and may be faulty;
- an LRCI device reported an error.
Automated Response
- If the LRCI device is not responding, the system will continue to run, but there will be no communication with this LRCI device.
If the LRCI device reported an error, the information is logged, and no further action is taken.
Impact
- Nothing is deconfigured.
Indicted Hardware
- No FRU is specified. The error message contains the identity of LRCI device.
Suggested Action for System Administrator
- Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.