Solution Type  Predictive Self-Healing Sure

Solution  1534751.1 :   M10-device.fail_pcibox_iob_ddc - A DDC on an IOB in PCI expansion box signaled that it has failed  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10 PCI Expansion Unit
SPARC

Purpose

Provide additional information for message ID: M10-device.fail_pcibox_iob_ddc

Fujitsu fault code:

11000015

Details

Type

Hardware Fault
   device.fail_pcibox_iob_ddc

Severity

Major

Description

A fault occurred when a DDC on an IOB in PCI expansion box signaled that it has failed.

Automated Response

The PCI expansion box is powered down. And, domain(s) using this PCI expansion box may face PCI fabric error when a PCI device in the PCI expansion box is accessed.

Impact

The IOB is deconfigured. This means, the PCI expansion box wil not start.

Indicted Hardware

The IOB is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)