M10-device.fail_pcibox_iob_ddc - A DDC on an IOB in PCI expansion box signaled that it has failed
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10 PCI Expansion Unit
SPARC
Purpose
Provide additional information for message ID: M10-device.fail_pcibox_iob_ddc
Fujitsu fault code:
11000015
Details
Type
- Hardware Fault
- device.fail_pcibox_iob_ddc
Severity
- Major
Description
-
A fault occurred when a DDC on an IOB in PCI expansion box signaled that it has failed.
Automated Response
- The PCI expansion box is powered down. And, domain(s) using this PCI expansion box may face PCI fabric error when a PCI device in the PCI expansion box is accessed.
Impact
- The IOB is deconfigured. This means, the PCI expansion box wil not start.
Indicted Hardware
- The IOB is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.