Synopsis
|
Last Modified Date
|
2391782.1 |
ILOM Out-of-Memory due to Nessus security scan |
2018-04-26
|
2391637.1 |
Unexpected reboot, ERROR: HV Abort: PC: 0x8a243dc - PowerDown |
2018-05-02
|
2368595.1 |
T4/T5 S11 System faults on the PCI/SCSI bus with a PCIEX-8000-0A and MPTSAS firmware errors |
2018-03-05
|
2348450.1 |
SPARC T4-2 server doesn't recognize it's Memory Risers and DIMM's |
2018-01-15
|
2326412.1 |
SPARC T4-1 - Sensor /SYS/MB/V_BAT not showing correct value |
2017-11-09
|
2313453.1 |
SNMP fails after OHMP upgrade to 2.4.1 |
2017-10-02
|
2285584.1 |
Memory Riser seeing SPT-8000-DH faults on SPARC TX-2 could cause all other memory risers and motherboard to fail the same way |
2018-05-22
|
2276802.1 |
QConvergeConsole CLI qaucli Slow Or Fails To Start |
2017-06-15
|
2272192.1 |
T4-x Cannot Boot After Patching |
Bug# 25265761
|
2243834.1 |
LDOM Virtual Function Configuration Lost For Fibre Channel HBAs - How To Create FC HBA VF With User-allocated WWN |
2017-12-13
|
2211740.1 |
Failing to add a new host config to SP using ldm add-config command |
2018-05-01
|
2208651.1 |
Troubleshooting high fan speed in T-series systems |
2018-05-22
|
2191885.1 |
Service Processor (SP) Web Browser User Interface Shows "Failed To Load Summary Page" |
2018-03-06
|
2189960.1 |
Firmware upgrade with existing faults from prior ILOM rev 3.2.6 to after results in misclassified Subsystem on T4-x, T5-x, & T7-x |
2018-01-12
|
2164409.1 |
SPARC: SMF-8000-YX: system/management/firmware-check:default is unavailable |
2017-10-05
|
2135699.1 |
Cannot Log In To Service Processor (SP) On T3/T4/T5, T5x20, T5x40 Servers: Too many users are logged in |
2018-03-06
|
2129776.1 |
The Onboard DVD on SPARC T4/T5 Can No Longer Be Seen after Updating to 11.3 SRU 0.175.3.3.0.2.0 |
2016-04-25
|
2128620.1 |
ASR/SFT Not Transferring All Explorers, Leaving Some Explorers In The Transfer Directory |
2016-04-19
|
2126841.1 |
Oracle Hardware Management Pack's (OHMP) fwupdate command fails to install older disk firmware patches. |
2017-12-14
|
2120758.1 |
Ignore T4-x ILOM's Master arbitration lost messages |
2017-07-12
|
2091155.1 |
Solaris SPARC Cannot Boot from FC HBA SAN Lun - Waiting for Login SFP state: 8Gb Present - Cannot init Link |
2018-03-07
|
2075211.1 |
Unable to start ilomconfig-interconnect Service: ILOM Not Reachable Over Internal LAN |
2018-03-06
|
2070764.1 |
300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. |
2017-07-17
|
2063882.1 |
Server Crash with ereport.cpu.generic-sparc.gchip-uc FMA showing SUN4V-8002-HR |
2017-05-09
|
2062950.1 |
Warning: /coredump is almost full On Servers With Service Processors Using ILOM Firmware |
2018-03-06
|
2061696.1 |
VTS tests exit with exit code 93 when Hardware Management Pack prior revision 2.3.2.4 installed |
2017-05-02
|
2045912.1 |
Service Processor (SP)/ILOM hang following installation of Oracle Hardware Management Pack 2.3.2 (or earlier) |
2017-05-17
|
2032772.1 |
T4-x: Values under /SP/clients/smtp Fail To Restore from Backup |
2018-03-06
|
2019500.1 |
System firmware upgrade via ILOM BUI fails with "Package Structure Is Corrupted" on T4 systems |
2017-10-08
|
2016900.1 |
ILOM Remote Serial Redirection Console Doesn't Work |
2017-05-01
|
2002924.1 |
System went down showing Erorrs SUN4V-8002-PX and SUN4V-8002-MJ |
2017-10-05
|
1994655.1 |
T4-2 - ILOM shows a SPT-8000-HR message and a failed MCU |
2018-05-09
|
1994249.1 |
Faulty IO Device with msg ID: PCIEX-8000-DJ |
2017-07-12
|
1994240.1 |
How to determine MCU0 or MCU1 is being flagged an error or false positive |
2018-05-09
|
1956704.1 |
T4-1/T4-2 panics with Fatal error has occured in: PCIe fabric.(0x1)(0x41) |
2017-05-01
|
1951488.1 |
T3-1/T3-2/T4-1/T4-2, System shut down due to ERROR: Unexpected zero POK value, adjusting state machine |
2018-02-14
|
1944663.1 |
T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port |
2018-03-13
|
1938327.1 |
Installing Solaris Via Install Server or Jumpstart Server Over VLAN Fails With "Connection timed out" |
2018-03-06
|
1930869.1 |
GM / vbsc.log flooded with "DEBUG: failed to check for data on "ipmi" LDC because it reset" |
2018-04-04
|
1923776.1 |
Oracle Critical Thread (CT) Optimizations in SPARC Sun4v Based Servers to Enhance Single-Threaded Performance |
2017-12-04
|
1922408.1 |
OBP Error (not preserving OBP environmental parameter value) |
2017-12-22
|
1674096.1 |
Setting 8bit colour depth with SPARC T3/T4 onboard graphics causes dtlogin to fail |
2017-10-11
|
1673533.1 |
SAS Disk Report Scsi Mpt_sas Warning : Failed To Copy Out Reply Data |
2018-01-01
|
1672818.1 |
Troubleshooting "Fatal error has occured in: PCIe fabric" panics on TX-X servers |
2017-10-04
|
1671764.1 |
Replacement disk managed by LSI not recognised by OS |
2018-02-26
|
1645197.1 |
ILOM NET MGT Does Not Connect To Network |
2017-08-16
|
1644336.1 |
SSH/Virtual Console hangs on guest domains configured to use Dynamic Resource Management |
2017-10-05
|
1643847.1 |
Primary disk label corrupt |
2017-03-17
|
1643464.1 |
[SPARC T3/T4/T5 and T7] OBP reports "One or more resources have been retired, please run 'show faulty' on the SP" on console |
2017-10-05
|
1643445.1 |
[SPARC T4/T5] ILOM 3.2.1.7: WEB GUI : Maintenance Firmware Upgrade fails on IE10 |
2017-10-05
|
1641425.1 |
[SPARC T4] prtdiag -v: LDOM Guest domain cpu speed is displayed as "-1446' MHz" |
2017-07-26
|
1634139.1 |
Non-Oracle GBIC (transceiver) causes no OS NIC data or improper operation |
2017-12-13
|
1627528.1 |
T-Series servers with LSI106x(e) (mpt driver) / LSI2x08 (mpt_sas driver) controllers reports "Command Timeout" for all internal disks (HDD/SSD) Caused by mpt/mpt_sas driver bug |
2018-03-06
|
1614738.1 |
[SPARC T4/T5/M5 and M6] FMA I/O retirement : PCI devices can be seen from OBP but disappear when System Boots up into Solaris |
2018-05-01
|
1613667.1 |
ILOM 3.2 NO LONGER sends the ILOM hostname to DHCP server on SPARC T3-x, SPARC T4-x, and SPARC T5-x servers |
2017-11-14
|
1612921.1 |
Non-zero ERRCNT and LNERR values could be seen during POST on either SPARC T4-1. SPARC T4-2, or SPARC T4-4 servers |
2017-10-05
|
1589203.1 |
T3/T4 missing memory before POST runs and reporting SPT-8000-HR FMA error messages |
2018-02-07
|
1588217.1 |
ILOM: Status of Hard Drives Not Available on SPARC T3/T4/T5 Systems |
2017-12-13
|
1587745.1 |
T3-x/T4-x systems might report "Speed mismatch detected, Invalid processor speed, Failed to margin" events after a MB and/or PM replacement during POST |
2017-12-13
|
1587056.1 |
ilomconfig modify in OHMP 2.2.7 is not working in XML files when comments present |
2018-03-06
|
1586616.1 |
Solaris 10 T4/T5 server with KU 147440-04 or later can hang or have performance issue with DISM |
2017-09-23
|
1583230.1 |
SPARC T3/T4/T5: usba:(hubd2): "Connecting device on port 3 failed" WARNING message reported at system boot |
2017-10-05
|
1582572.1 |
Oracle Hardware Management Pack (OHMP) does not report Storage details |
2017-08-07
|
1580033.1 |
SP Resets on T5xx0, T3, T4, T5 and M5 Systems May Overwrite a User-Land Solaris Memory Page Causing In-Memory Corruption |
2018-01-22
|
1577361.1 |
Downgrading system firmware invalidates the TLI with FDD/FMA reporting the following faults [ fault.chassis.tli.invalid, ILOM-8000-30] |
2017-09-29
|
1571692.1 |
SPARC T4 system panic due to send_mondo timeout |
2017-08-16
|
1571215.1 |
Analysis of error message "WARNING: consconfig: cannot find driver for screen device" |
2017-11-27
|
1571110.1 |
SPARC T3/T4 Servers - PCIe Host Bus Adapter (HBA) Disappears During Reboot |
2015-07-27
|
1566851.1 |
USB faults seen on T3 or T4 platforms during boot of Operating System |
2017-08-16
|
1565509.1 |
T3/T4 Servers: Spurious Interrupt from USB on ino 0x1 / 0x2 / 0x4 |
2018-03-06
|
1565363.1 |
T3 and T4 servers using Hardware RAID can have "Volume Not Consistent" status in OBP |
2017-04-20
|
1565154.1 |
Access Loss To SP During Sysfw Upgrade |
2017-10-05
|
1551633.1 |
iostat H/W Errors Increment for Multipathed Disks due to "SCSI Sense Key: Unit_Attention ASC: 0x2a (parameters changed), ASCQ: 0x0" when ZFS Modifies the Write Cache Mode |
2017-11-02
|
1540994.1 |
Intermittently new system time(tod offset) is not saved when T3-1, T3-1B, T3-2, T3-4, T4-1, T4-1B, T4-2, T4-4 systems/blades are power downed |
2017-11-15
|
1539729.1 |
Error "set: Unable to configure network" when trying to configure/change ILOM network parameters |
2018-01-16
|
1537665.1 |
T3 and T4 systems may panic due to a NULL iv_handler |
2017-09-23
|
1530956.1 |
Bug 15971695 Sconfig Reset While Upgrading From ILOM 8.2.0.f To 8.2.1.b on T3 and T4 systems |
2017-10-05
|
1523297.1 |
SP (ILOM) enters "ILOM Pre-boot Menu" (Preboot>) after "reset /SP"; Boots fine from a cold start (unplug/plugin power cords) |
2017-10-05
|
1520628.1 |
T3-x T4-x Powering down due to Redstate |
2018-02-23
|
1519049.1 |
ILOM Stuck in "Primary Bootstrap" Loop Preventing Server Power On (SPARC T4-1/T4-2/T4-4) |
2017-10-05
|
1517832.1 |
ILOM events not captured in OS |
2018-01-16
|
1517032.1 |
T3-x, T4-x, T5-x, T7-x: Unrecognized Chassis: This Module Is Installed In An Unknown Or Unsupported Chassis. |
2018-03-05
|
1504917.1 |
ilomconfig requests between the host and SP fail with "ERROR: ILOM not supported on this system" |
2017-10-05
|
1499129.1 |
Sporadic Hot Removal and Insertion of /SYS/SASBP/HDDx SC Alerts Reported on T3/T4 servers |
2017-09-13
|
1483873.1 |
Service Processor is Faulted and Not Accessible (SPARC T3-1/T3-2/T3-4/T3-1B/T4-1/T4-2/T4-4/T4-1B/Netra T3-1/Netra T3-1B/Netra T4-1/Netra T4-2) |
2017-12-13
|
1479666.1 |
Intermitently new SPARC T3 & T4 system time(tod offset) is not saved when system is power downed |
2017-11-15
|
1471121.1 |
Some or all internal disks in SPARC T3 / T4 Servers may not show up in "# format" or "ok> probe-scsi-all" |
2018-03-06
|
1363950.1 |
Solaris 10 8/11 Hangs on Boot From Hardware RAID 1 or RAID 1E Mirrors On SPARC CMT Systems |
2017-11-30
|