Solution Type Problem Resolution Sure Solution 2326412.1 : SPARC T4-1 - Sensor /SYS/MB/V_BAT not showing correct value
V_BAT Alarms the Server, battery is showing constant messages about "/SYS/MB/V_BAT : Lower Non-critical going low" and a few seconds later "/SYS/MB/V_BAT : Lower Non-critical going high " In this Document
Created from <SR 3-16007152787> Applies to:SPARC T4-1 - Version All Versions to All Versions [Release All Releases]SPARC T4-2 - Version All Versions to All Versions [Release All Releases] SPARC T4-4 - Version All Versions to All Versions [Release All Releases] Netra SPARC T4-1 Server - Version All Versions to All Versions [Release All Releases] Netra SPARC T4-2 Server - Version All Versions to All Versions [Release All Releases] Oracle Solaris on SPARC (64-bit) Battery had been replaced 2 months before the alarm SymptomsEvent list shows "/SYS/MB/V_BAT : Lower Non-critical going low" and a few seconds later "/SYS/MB/V_BAT : Lower Non-critical going high ", "show faulty" displays event ID SPT-8000-G3. Battery was showing lower voltage:
ChangesMB Battery had been replaced 2 months ago, battery should not be failling so soon. CauseFW was upgraded from System Firmware 8.6.0.b to System Firmware 8.9.9, thus resolving the issue described in bug With the new Firmware battery was showing a higher voltage:
SolutionIssue was resolved by upgrading FW above 8.9.5 no need to replace battery References<BUG:23271415> - LINEARIZATION FOR V_BAT NEEDS TO BE ADJUSTEDAttachments This solution has no attachment |
||||||||||||||||||||
|