Solution Type Problem Resolution Sure Solution 1519049.1 : ILOM Stuck in "Primary Bootstrap" Loop Preventing Server Power On (SPARC T4-1/T4-2/T4-4)
In this Document
Created from <SR 3-6354514971> Applies to:SPARC T4-4 - Version All Versions to All Versions [Release All Releases]SPARC T4-2 - Version All Versions to All Versions [Release All Releases] SPARC T4-1 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsILOM stuck in a loop reporting "Primary Bootstrap" during initialisation. CauseFollowing a reset the Service Processor fails to initialise, reporting the following bootstrap events to the serial management port; U-Boot 1.1.4
Custom AST2100 U-Boot 3.0 (Aug 3 2012 - 11:25:23) r75067 --- Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. Primary Bootstrap. U-Boot 1.1.4 Custom AST2100 U-Boot 3.0 (Aug 3 2012 - 11:25:23) r75067
SolutionReplace the Service Processor : How to Remove and Replace a SPARC T4-4 Server Service Processor References<NOTE:1416353.1> - How to Remove and Replace a SPARC T4-4 Server Service Processor:ATR:1416353.1:1Attachments This solution has no attachment |
||||||||||||||||||
|