Solution Type  Problem Resolution Sure

Solution  2061696.1 :   VTS tests exit with exit code 93 when Hardware Management Pack prior revision 2.3.2.4 installed  


Related Items
  • SPARC T4-2
  •  
  • SPARC T5-2
  •  
  • SPARC T5-4
  •  
  • SPARC T4-1
  •  
  • SPARC T4-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




Created from <SR 3-11376247381>

Applies to:

SPARC T4-2 - Version All Versions and later
SPARC T5-2 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
SPARC T4-1 - Version All Versions and later
SPARC T4-4 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

VTS fails with exit code 93 during FPU or IU tests within 24 hours:

09/09/15 04:21:52 BOS-T5-2 SunVTS7.0ps19.2: VTSID 6427 vtsk.ERROR : Processor.fputest.0[FPU] (pid=17717) exited with exit code: 93 during task 808406.

Cause

Hardware Management Pack (HMP) interfered with VTS, by consuming processes.

Solution

The solution is to upgrade HMP to revision 2.3.2.4 at a minimum. 

This problem can also be resolved by disabling the HMP service:

svcadm disable svc:/system/sp/management:default
svcadm refresh svc:/system/sp/management:default
svcs -l svc:/system/sp/management:default