Solution Type
Problem Resolution Sure
Solution
1922408.1
:
OBP Error (not preserving OBP environmental parameter value)
Related Items |
- SPARC T4-1
- SPARC T4-2
- SPARC T4-4
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T4
|
In this Document
Created from <SR 3-9354470001>
Applies to:
SPARC T4-1 - Version All Versions to All Versions [Release All Releases]
SPARC T4-2 - Version All Versions and later
SPARC T4-4 - Version All Versions and later
Information in this document applies to any platform.
Symptoms
{0} ok setenv auto-boot? false
WARNING: Error storing configuration variable. No space left, check SP and other logs
Configuration variable setting will not persist after a reset or power cycle
auto-boot? = false
{0} ok
=========
the ilom not setting the "script" property.
-> cd /HOST/bootmode
/HOST/bootmode
-> show
/HOST/bootmode
Targets:
Properties:
config = factory-default
expires = (none)
script = (none)
state = normal
-> set script="setenv auto-boot? false"
Set 'script' to 'setenv auto-boot? false'
-> show
/HOST/bootmode
Targets:
Properties:
config = factory-default
expires = (none)
script = (none)
state = normal
Changes
None
Cause
This could be due to corruption in ILOM firmware.
Please verify the same as below:
1) In snapshot data, check spos_info directory, for '@bin@df_-k.out' to see usage of /coredump
/dev/mtdblock6 12288 1808 10480 15% /coredump
## The SP filesystem was not full.
2) In snasphot data, event logs check if they tried fw upgrade.
704 Wed Jul 16 07:58:32 2014 Power On major
Power to /SYS has been turned on by: SP, Reason: Firmware update complete
700 Wed Jul 16 07:54:52 2014 Power Reset major
/SP has been reset by: SP, Reason: Firmware update complete
691 Wed Jul 16 07:49:42 2014 Power Off major
Power to /SYS has been turned off by: SP, Reason: Firmware update failed
## The firmware was upgraded on the system.
Solution
1) Reflash the ilom firmware with saving the configuration.
2) Check if it works, else re-flash firmware without saving the current configuration. i.e.
--> Back up ilom configuration using 'set dump_uri=ftp://<user>:<password>@hostIP/tmp/file.config'
--> Try re-flashing the System Firmware without saving the current configuration (Please don't select the preserve the settings)
--> Check if it works, then restore the configuration by 'set load_uri=ftp://<user>:<password>@hostIP/tmp/file.config', else next step.
--> Set System to factory defaults using 'set /SP reset_to_defaults=factory'.
--> Check if it works, then restore the configuration by 'set load_uri=ftp://<user>:<password>@hostIP/tmp/file.config', else next step.
--> Log a Service Request with Oracle Support to resolve this issue.
The SP was replaced and the issue got fixed
Attachments
This solution has no attachment