Asset ID: |
1-72-1613667.1 |
Update Date: | 2017-11-13 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1613667.1
:
ILOM 3.2 NO LONGER sends the ILOM hostname to DHCP server on SPARC T3-x, SPARC T4-x, and SPARC T5-x servers
Related Items |
- SPARC T3-4
- SPARC T4-1
- SPARC T3-1B
- SPARC T3-2
- SPARC T5-4
- SPARC T4-1B
- SPARC T5-2
- SPARC T4-4
- SPARC T3-1
- SPARC T4-2
- SPARC T5-8
- SPARC T5-1B
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T3
|
In this Document
Created from <SR 3-7810014501>
Applies to:
SPARC T4-1B - Version All Versions to All Versions [Release All Releases]
SPARC T5-2 - Version All Versions to All Versions [Release All Releases]
SPARC T5-4 - Version All Versions to All Versions [Release All Releases]
SPARC T5-8 - Version All Versions to All Versions [Release All Releases]
SPARC T5-1B - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
ILOM 3.2 NO LONGER sends the ILOM hostname to DHCP. Without this information it's very difficult to update DNS with the ILOM hostname. We tried manually setting the SP hostname variable and did not appear to make any difference. We are expecting that when the system sends a DHCP request to the Server, it will send the ORACLESP-xxxxxxx name which they then use that to update their Dynamic DNS server.
See service processor network properties below under dhcp_server_ip where it says "none" and should show the DHCP server ip address:
/SP/network
Properties:
commitpending = (Cannot show property)
dhcp_clientid = none
dhcp_server_ip = (none) <<<<<<
ipaddress = 10.177.118.121
ipdiscovery = dhcp
ipgateway = 10.177.112.1
ipnetmask = 255.255.248.0
macaddress = 00:21:28:D2:8F:75
managementport = MGMT
outofbandmacaddress = 00:21:28:D2:8F:75
pendingipaddress = 10.177.118.121
pendingipdiscovery = dhcp
pendingipgateway = 10.177.112.1
pendingipnetmask = 255.255.248.0
pendingmanagementport = MGMT
sidebandmacaddress = 00:21:28:D2:8F:74
state = enabled
Cause
Blades/Servers with the following system firmwares:
SPARC T3-1B Patch 150410-01, -02, -03 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d
SPARC T3-1 Patch 150407-01, -02, -03 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d
SPARC T3-2 Patch 150408-01, -02, -03 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d
SPARC T3-4 Patch 150409-01, -02, -03 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d
SPARC T4-1B Patch 150416-01, -02, -03 & Patch 150679-01 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d & 8.4.0.a
SPARC T4-1 Patch 150413-01, -02, -03 & Patch 150676-01, -02 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d & 8.4.0.a, 8.4.0.b
SPARC T4-2 Patch 150414-01, -02, -03 & Patch 150677-01, -02 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d & 8.4.0.a, 8.4.0.b
SPARC T4-4 Patch 150415-01, -02, -03 & Patch 150678-01 FW Version 8.3.0.b, 8.3.0.c, 8.3.0.d & 8.4.0.a
SPARC T5-1B Patch 16588946, 16880751, 17199947, 17019075, 17264114 FW Version 9.0.0.d, 9.0.0.i, 9.0.0.k, 9.0.2.g, 9.1.0.b
SPARC T5-2 Patch 16588794, 16880749, 17199954, 17019079, 17264122, 17504410 FW Version 9.0.0.h, 9.0.0.i, 9.0.0.k, 9.0.2.g, 9.1.0.b, 9.1.0.f
SPARC T5-4 Patch 16588968, 16880761, 17199962, 17019069, 17264131, 17504407 FW Version 9.0.0.h, 9.0.0.i, 9.0.0.k, 9.0.2.g, 9.1.0.b, 9.1.0.f
SPARC T5-8 Patch 16588968, 16880761, 17199962, 17019069, 17264131, 17504407 FW Version 9.0.0.h, 9.0.0.i, 9.0.0.k, 9.0.2.g, 9.1.0.b, 9.1.0.f
Solution
Install the following system firmwares on the below Blades/Servers:
SPARC T3-1B Patch 150410-05 FW Version 8.3.1.b (or later)
SPARC T3-1 Patch 150407-05 FW Version 8.3.1.b (or later)
SPARC T3-2 Patch 150408-05 FW Version 8.3.1.b (or later)
SPARC T3-4 Patch 150409-05 FW Version 8.3.1.b (or later)
SPARC T4-1B Patch 150679-02 FW Version 8.4.0.c (or later)
SPARC T4-1 Patch 150676-03 FW Version 8.4.0.c (or later)
SPARC T4-2 Patch 150677-03 FW Version 8.4.0.c (or later)
SPARC T4-4 Patch 150678-02 FW Version 8.4.0.c (or later)
SPARC T5-1B Patch 17944126 FW Version 9.1.1 (or later)
SPARC T5-2 Patch 17944106 FW Version 9.1.1 (or later)
SPARC T5-4 Patch 17944111 FW Version 9.1.1 (or later)
SPARC T5-8 Patch 17944111 FW Version 9.1.1 (or later)
References
<BUG:17518811> - ILOM 3.2 NO LONGER SENDS THE ILOM HOSTNAME TO DHCP SERVER
Attachments
This solution has no attachment