Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2016900.1
Update Date:2017-05-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2016900.1 :   ILOM Remote Serial Redirection Console Doesn't Work  


Related Items
  • Netra SPARC T4-2 Server
  •  
  • Netra SPARC T4-1 Server
  •  
  • SPARC T4-1
  •  
  • SPARC T4-4
  •  
  • SPARC T4-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T4
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-10838365498>

Applies to:

SPARC T4-4 - Version All Versions to All Versions [Release All Releases]
Netra SPARC T4-2 Server - Version All Versions to All Versions [Release All Releases]
Netra SPARC T4-1 Server - Version All Versions to All Versions [Release All Releases]
SPARC T4-1 - Version All Versions to All Versions [Release All Releases]
SPARC T4-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

The console redirection doesn't work.

In some cases, the screen just shows colourful 'snow':

ILOM Console Example with colourful snow

Changes

 A recent update to 8.6.0.b or system at 8.6.0.b

Cause

 This is a problem with firmware 8.6.0.b that prevents serial redirection

Solution

Solution is to either upgrade to 8.7.2.b (recommended) or downgrade to 8.5.1.b.
 

References

<BUG:20281129> - CAN'T CONNECT TO SERIAL CONSOLE ON AST BASED SYSTEMS

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.