Symptoms

After upgrade to firmware 8.6.0 or above on a T4-x server, ILOM message "Master arbitration lost" is sometimes seen in a Snapshot.

Cause

 The firmware incorrectly outputs this message which relates to a different type of server.

Solution

 Ignore this message.  The related firmware will not be corrected.