Problem Document
|
Synopsis
|
Last Modified Date
|
2391782.1 |
ILOM Out-of-Memory due to Nessus security scan |
2018-04-26
|
2370600.1 |
ILOM webgo corefiles + fault ILOM-8000-JV |
2018-04-20
|
2368595.1 |
T4/T5 S11 System faults on the PCI/SCSI bus with a PCIEX-8000-0A and MPTSAS firmware errors |
2018-03-05
|
2339410.1 |
T5-2 System shows Unexpected Event 8400 ff000XXX right after the banner on boot |
2017-12-18
|
2337951.1 |
SPARC T5-2 powered down and reported FMA fault SPT-8000-J4 |
2018-05-01
|
2334426.1 |
T5-2 Messages File Shows Short Sensor Limit Violation Not seen on ILOM |
2017-12-06
|
2313453.1 |
SNMP fails after OHMP upgrade to 2.4.1 |
2017-10-02
|
2301011.1 |
ILOM Reboots due to Out of Memory or Hangs after ILOM 3.2.4 fixes |
2018-05-07
|
2287852.1 |
ILOM Interconnect Fault FMD-8000-D6 occurs after Solaris Upgrade |
2017-07-20
|
2285584.1 |
Memory Riser seeing SPT-8000-DH faults on SPARC TX-2 could cause all other memory risers and motherboard to fail the same way |
2018-05-22
|
2276802.1 |
QConvergeConsole CLI qaucli Slow Or Fails To Start |
2017-06-15
|
2268011.1 |
CM1 resources are reported missing on a single socket T5-2 (T5-2 1S) |
2018-05-01
|
2245358.1 |
Solaris sun4v domains may panic after 1101 days of uptime |
2018-01-18
|
2243834.1 |
LDOM Virtual Function Configuration Lost For Fibre Channel HBAs - How To Create FC HBA VF With User-allocated WWN |
2017-12-13
|
2213399.1 |
A number of SPARC T5 servers shipped without fully completing the factory's sys-unconfig process. This resulted in failure to setup the HOST preinstalled OS |
2018-03-28
|
2211740.1 |
Failing to add a new host config to SP using ldm add-config command |
2018-05-01
|
2208651.1 |
Troubleshooting high fan speed in T-series systems |
2018-05-22
|
2191885.1 |
Service Processor (SP) Web Browser User Interface Shows "Failed To Load Summary Page" |
2018-03-06
|
2189960.1 |
Firmware upgrade with existing faults from prior ILOM rev 3.2.6 to after results in misclassified Subsystem on T4-x, T5-x, & T7-x |
2018-01-12
|
2164409.1 |
SPARC: SMF-8000-YX: system/management/firmware-check:default is unavailable |
2017-10-05
|
2157839.1 |
ql_async_event, 8014h Port Database Update, Login/Logout received, mbx1=bh, mbx2=7h, mbx3=1700h |
2016-07-12
|
2156331.1 |
Qaucli Command Hangs When Trying to Upgrade a Qlogic CNA |
2018-02-08
|
2149606.1 |
Solaris ipfilter settings can block traffic between Host and Service Processor causing "prtdiag -v" to lose environmental data and picld to report "PICL snmpplugin: cannot fetch object value" |
2018-05-10
|
2136834.1 |
M10-x, Mx-32,T4-x, T5-x Servers: ldmd_start Fails with Error "timeout waiting for op HVctl_op_hello" |
2018-02-12
|
2135699.1 |
Cannot Log In To Service Processor (SP) On T3/T4/T5, T5x20, T5x40 Servers: Too many users are logged in |
2018-03-06
|
2134410.1 |
CNA FCoE Universal Emulex HBA link down - ERROR: 530: Mailbox timeout. (HEARTBEAT: Nowait.) on both ports |
2018-03-07
|
2129776.1 |
The Onboard DVD on SPARC T4/T5 Can No Longer Be Seen after Updating to 11.3 SRU 0.175.3.3.0.2.0 |
2016-04-25
|
2119504.1 |
emlxs WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) - FC HBA Firmware Upgrade Example |
2017-09-19
|
2119085.1 |
T5-2 : Disk LED's not operational : All the disks are working normal without any LED's. |
2017-07-12
|
2108027.1 |
Solaris 11 systems showing a different Serial Number when activating ASR |
2016-02-23
|
2092329.1 |
SPARC T5-2 Power Supply SPT-8000-MJ faults triggered by V_OUT_OK (V_IN_INFO) de-asserted events |
2018-01-19
|
2089407.1 |
16Gb Qlogic HBA shows WARNING: fp(x)::Topology Unknown, Offlining the port |
2018-04-05
|
2087929.1 |
Unable to establish FCoE connection using second port of CNA to Cisco Nexus 5548 switch |
2015-12-14
|
2087334.1 |
SPARC T5-2: prtdiag -v : ILOM environmental and firmware information is missing |
2017-10-05
|
2070764.1 |
300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. |
2017-07-17
|
2061696.1 |
VTS tests exit with exit code 93 when Hardware Management Pack prior revision 2.3.2.4 installed |
2017-05-02
|
2029948.1 |
Solaris 11 - After Expanding EMC LUN : Corrupt label - bad geometry - Label says 681561600 blocks; Drive says 419430400 blocks |
2017-05-23
|
2029693.1 |
Brocade FC Switch Can Cause Link Reset for Credit Recovery on F_Ports (Slow Drain Device) |
2018-03-07
|
2021743.1 |
T5-x ILOM reports spurious V_IN_WARN asserted / deasserted events |
2018-01-02
|
2003977.1 |
Constant errors of "PICL Snmpplugin: Snmp Ds Reset Happened, Rebuilding Tree" |
2018-03-20
|
1997499.1 |
EMC Power Path Multipathing device (emcpowerxx) is not listed in format like others. |
2015-04-15
|
1996519.1 |
SPARC T5-2: boot hangs at 'Control-get failed' if improper voltage supplied |
2017-07-26
|
1955391.1 |
T5-x ILOM unaccessible via SSH or HTTPs |
2018-03-08
|
1948940.1 |
On SPARC T5-2, removing bus with usbecm device (pci_1 / pci@340) from primary/control domain can impact FMA and ldmd processing |
2017-11-29
|
1946680.1 |
A Rebooted IO Domain Reports: "WARNING: fp0: online_driver fp failed" |
2014-11-25
|
1944663.1 |
T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port |
2018-03-13
|
1943535.1 |
USB FMA error "Fault class : fault.io.usb.eps" |
2017-10-05
|
1938327.1 |
Installing Solaris Via Install Server or Jumpstart Server Over VLAN Fails With "Connection timed out" |
2018-03-06
|
1930869.1 |
GM / vbsc.log flooded with "DEBUG: failed to check for data on "ipmi" LDC because it reset" |
2018-04-04
|
1923776.1 |
Oracle Critical Thread (CT) Optimizations in SPARC Sun4v Based Servers to Enhance Single-Threaded Performance |
2017-12-04
|
1921706.1 |
Configuring FC HBA SAN Boot Fails With "Not supported in qlc mode" When Setting boot-id |
2018-03-07
|
1915487.1 |
HV Abort on guest domain shutdown |
2017-10-05
|
1676282.1 |
QLogic Dual 16Gigabit/Sec Fibre Channel / 10Gbps FCoE Host Adapter unable To Log Into Switch |
2016-01-14
|
1672818.1 |
Troubleshooting "Fatal error has occured in: PCIe fabric" panics on TX-X servers |
2017-10-04
|
1669763.1 |
SPARC T5 Running Solaris 10 May Panic When Connecting An External USB Tape Drive |
2018-02-06
|
1645197.1 |
ILOM NET MGT Does Not Connect To Network |
2017-08-16
|
1643847.1 |
Primary disk label corrupt |
2017-03-17
|
1643464.1 |
[SPARC T3/T4/T5 and T7] OBP reports "One or more resources have been retired, please run 'show faulty' on the SP" on console |
2017-10-05
|
1643445.1 |
[SPARC T4/T5] ILOM 3.2.1.7: WEB GUI : Maintenance Firmware Upgrade fails on IE10 |
2017-10-05
|
1642066.1 |
ixgbe interface faulted because of message "Problem: Network adapter has been stopped because it has overheated" |
2017-07-11
|
1634139.1 |
Non-Oracle GBIC (transceiver) causes no OS NIC data or improper operation |
2017-12-13
|
1627528.1 |
T-Series servers with LSI106x(e) (mpt driver) / LSI2x08 (mpt_sas driver) controllers reports "Command Timeout" for all internal disks (HDD/SSD) Caused by mpt/mpt_sas driver bug |
2018-03-06
|
1626351.1 |
[SPARC T5] "virtinfo -a" displays "unknown" Control Domain and Chassis Serial# |
2017-07-26
|
1621104.1 |
Solaris 11 ISC DHCP: SPARC T5/T4 and T3 server fails network boot/network AI install at OBP with BOOTP/DHCP timeout |
2017-10-05
|
1620574.1 |
SPARC T5:S10 U11: SPT-8000-KQ :Identifying which Power Supply has a faulty fan in Solaris |
2017-10-05
|
1617956.1 |
I/O SERD threshold values are set too low and may result in PCIEX-8000-J5, PCIEX-8000-YJ and PCIEX-8000-KP faults. |
2017-08-22
|
1614738.1 |
[SPARC T4/T5/M5 and M6] FMA I/O retirement : PCI devices can be seen from OBP but disappear when System Boots up into Solaris |
2018-05-01
|
1613667.1 |
ILOM 3.2 NO LONGER sends the ILOM hostname to DHCP server on SPARC T3-x, SPARC T4-x, and SPARC T5-x servers |
2017-11-14
|
1613206.1 |
SPARC T5-X at System Firmware 9.1.1 Downgrade or Re-flash firmware using BUI method may fail. |
2017-05-09
|
1612672.1 |
SPARC T5 System :FMA reports SUNOS-8000-FU or SUNOS-8000-J0 due to ereport.io.pciex.rc.ce-msg |
2018-05-01
|
1612145.1 |
certain ixgbe interfaces do not auto-negotiate to gigabit speed with some switches |
2018-05-09
|
1604929.1 |
PCIEX-8000-MH causing AMBER LED On, on T5-x Systems |
2017-08-16
|
1603333.1 |
Identify cause of PCIEX-8000-0A PCIe event |
2017-10-05
|
1594669.1 |
Minimum Solaris version for Oracle VM for SPARC 3.1 on SPARC T5 |
2017-10-05
|
1588217.1 |
ILOM: Status of Hard Drives Not Available on SPARC T3/T4/T5 Systems |
2017-12-13
|
1586616.1 |
Solaris 10 T4/T5 server with KU 147440-04 or later can hang or have performance issue with DISM |
2017-09-23
|
1586490.1 |
Unable To configure ILOM Net MGMT port - Unable to get network management property |
2018-01-22
|
1583230.1 |
SPARC T3/T4/T5: usba:(hubd2): "Connecting device on port 3 failed" WARNING message reported at system boot |
2017-10-05
|
1581135.1 |
Oracle VM guest bind failure due to Direct I/O device in an Unknown (UNK) state. |
2017-10-05
|
1580033.1 |
SP Resets on T5xx0, T3, T4, T5 and M5 Systems May Overwrite a User-Land Solaris Memory Page Causing In-Memory Corruption |
2018-01-22
|
1578024.1 |
ereport.io.usb.epse USB endpoint stall event |
2017-10-05
|
1574004.1 |
SPARC T5 fails to power on with ILOM FMA diagnosing SPSUN4V-8000-RQ / fault.chassis.no-cpus-signed-on |
2018-05-01
|
1571692.1 |
SPARC T4 system panic due to send_mondo timeout |
2017-08-16
|
1568737.1 |
SPARC T5-2 systems could see "WARNING: " messages on console after executing "setenv" at the "ok>" with system firmware 9.0.0.h |
2017-11-15
|
1567869.1 |
SPARC T5-2 : After multiple coin battery replacement the server still reports SPT-8000-G3 (fault.chassis.battery.fail) |
2017-10-05
|
1567072.1 |
Workaround Options for Guest Domains Running Solaris 11.1.7.5.0 (or greater) on T5 and M5 Systems and Live Migration |
2016-09-08
|
1558092.1 |
Emulex FC HBA initialization "ERROR: 530: Mailbox timeout. (RUN_BIU_DIAG64: mb=10014f767980 tmo=30 Polled.)" |
2018-01-07
|
1531113.1 |
T-Series Servers: Solaris messages files filled with SC Alert: Audit events (Open, Close, Activate Session) |
2017-10-05
|
1517032.1 |
T3-x, T4-x, T5-x, T7-x: Unrecognized Chassis: This Module Is Installed In An Unknown Or Unsupported Chassis. |
2018-03-05
|