Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2119504.1
Update Date:2017-09-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  2119504.1 :   emlxs WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) - FC HBA Firmware Upgrade Example  


Related Items
  • Oracle Server X5-2
  •  
  • Emulex FC HBA
  •  
  • SPARC T7-2
  •  
  • SPARC T5-2
  •  
  • SPARC T4-1
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-12241187781>

Applies to:

SPARC T5-2 - Version All Versions and later
Emulex FC HBA - Version All Versions and later
Oracle Server X5-2 - Version All Versions and later
SPARC T4-1 - Version All Versions and later
SPARC T7-2 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Physical media (SFP+ Manufacturing Part Number 7023053) not detected by Oracle Sun Storage 16 Gb Fibre Channel PCIe Universal HBA from Emulex. For example:

Feb 24 14:24:49 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs3: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off)
Feb 24 14:24:49 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs0: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs3: NOTICE: 730: Link reset.
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1B9F]emlxs3: NOTICE: 100: Driver attach. (Copyright (c) 2004-2014 Emulex. All rights reserved.)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LP10000-S: v1.92a1 (td192a1.all))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LP11000-S: v2.82a4 (bd282a4.all))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LP11002-S: v2.82a4 (bf282a4.all))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LPe11000-S: v2.82a4 (zd282a4.all))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LPe11002-S: v2.82a4 (zf282a4.all))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LPe12000-S: v2.01a12 (ud201a12.all))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs3: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs3: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs3: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs3: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs3: NOTICE: 100: Driver attach. (WWPN:10000090FA87652B WWNN:20000090FA87652B)
Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs3
Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs3
Feb 24 14:24:51 HOST genunix: [ID 936769 kern.info] emlxs3 is /pci@0,0/pci8086,2f04@2/pci10df,e20e@0,1
Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs3
Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs3
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs3:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs0: NOTICE: 730: Link reset.
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs0: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00))
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs0: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs0: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs0: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs0: NOTICE: 100: Driver attach. (WWPN:10000090FA87651A WWNN:20000090FA87651A)
Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs0
Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs0
Feb 24 14:24:51 HOST genunix: [ID 936769 kern.info] emlxs0 is /pci@0,0/pci8086,2f02@1/pci10df,e20e@0
Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs0
Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs0
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs2: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs1: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off)
Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs3: NOTICE: 730: Link reset. (Resetting link...)
Feb 24 14:24:52 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs3: NOTICE: 730: Link reset.
Feb 24 14:24:52 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs3:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs2: NOTICE: 730: Link reset.
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs2: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00))
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs2: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs2: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs2: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs2: NOTICE: 100: Driver attach. (WWPN:10000090FA87652A WWNN:20000090FA87652A)
Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs2
Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs2
Feb 24 14:24:53 HOST genunix: [ID 936769 kern.info] emlxs2 is /pci@0,0/pci8086,2f04@2/pci10df,e20e@0
Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs2
Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs2
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs2:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs2: NOTICE: 730: Link reset. (Resetting link...)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs1: NOTICE: 730: Link reset.
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs1: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00))
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs1: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs1: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs1: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs1: NOTICE: 100: Driver attach. (WWPN:10000090FA87651B WWNN:20000090FA87651B)
Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs1
Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs1
Feb 24 14:24:53 HOST genunix: [ID 936769 kern.info] emlxs1 is /pci@0,0/pci8086,2f02@1/pci10df,e20e@0,1
Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs1
Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs1
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs1: NOTICE: 730: Link reset. (Resetting link...)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs0: NOTICE: 730: Link reset. (Resetting link...)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs2: NOTICE: 730: Link reset.
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs2:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs1: NOTICE: 730: Link reset.
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs0: NOTICE: 730: Link reset.
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)

 

Changes

Initially, the Oracle Sun Storage 16 Gb Fibre Channel PCIe Universal HBA from Emulex only shipped with and supported Fibre Channel Physical Media Optic Emulex Part Number AFBR-57F5MZ-ELX.

% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd GetXcvrData 10:00:00:90:fa:2e:e1:82
VendorName: EMULEX
VendorOui: 00-17-6a
VendorPN: AFBR-57F5MZ-ELX
VendorRev:
VendorSN: AA1209J02L2
DateCode: 120302
Identifier: 3h
ExtIdentifier: 4h
Connector: 7h
Wavelength: 850 nm
Temperature: 37.73 C
Vcc: 3.31 V
TxBiasCurrent: 7.43 mA
TxPower: 0.58 mW
RxPower: 0.46 mW

Avago Emulex Connectivity Division of Broadcom Limited added support for Fibre Channel Physical Media Optic FINISAR CORPORATION Part Number FTLF8529P3BCV-EM in firmware version 10.6.230.0.

% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd GetXcvrData 10:00:00:90:FA:87:65:1A
VendorName: FINISAR CORP.
VendorOui: 00-90-65
VendorPN: FTLF8529P3BCV-EM
VendorRev: B
VendorSN: USL0Q6B
DateCode: 141116
Identifier: 3h
ExtIdentifier: 4h
Connector: 7h
Wavelength: 850 nm
Temperature: 44.64 C
Vcc: 3.41 V
TxBiasCurrent: 0.00 mA
TxPower: 0.00 mW
RxPower: 0.54 mW

 

NOTE: TxPower is 0.00 mW when unsupported physical media is installed.

 

Cause

A minimum of firmware version 10.6.230.0 is required to support FINISAR CORPORATION Part Numbers FTLF8529P3BCV-EM and FTLX8571D3BCL-EM.

In summary, the supported Fibre Channel optics:

VENDOR_OUI_FINISAR
FINISAR
FTLF8529P3BCV-EM

VENDOR_OUI_AVAGO
EMULEX
AFBR-57F5MZ-ELX

The supported Ethernet optics:

VENDOR_OUI_FINISAR
FINISAR
FTLX8571D3BCL-EM

VENDOR_OUI_AVAGO
AVAGO
AFBR-703SDZ-ELX

Solution

FIRMWARE PACK

As an alternative to the Multi-Boot Image Update Kit on the Oracle OEM portion of the Broadcom Emulex Connectivity Division (ECD) website, some platforms now offer a firmware pack. For example, Patch 26413467 Oracle Server X5-2 SW 1.10.0 - FIRMWARE PACK also now includes updated firmware for the platform as well as Fibre Channel and SAS HBAs, disk, etc.

Oracle Server X5-2

Software Release: 1.10.0.87089
Build Date: Tue Jun 20 00:02:54 PDT 2017

Firmware
--------
ILOM / BIOS Firmware : 3.2.10.22-r118277
7101674 Sun Storage 16 Gb Fibre Channel PCIe Universal HBA, QLogic : 8.05.00
7101684 Sun Storage 16 Gb Fibre Channel PCIe Universal HBA, Emulex : 11.1.218.17
Firmware for Oracle Storage 12Gb/s SAS PCIe HBA, External : 13.00.00.00-000B
Firmware for Oracle Storage 12Gb/s SAS PCIe HBA, Internal : 13.00.00.00-000D
Oracle Storage 12 Gb SAS PCIe RAID HBA Firmware : 4.650.00-7176
Firmware for Oracle QDR Infiniband Adapter M3 : 2.11.1280
Firmware for H101212SESUN1.2T : A720
Firmware for H109060SESUN600G : A7E0
Firmware for HSCAC2DA4SUN400G : A29A
Firmware for Oracle Flash Accelerator F160 PCIe Card and Oracle 1.6TB NVMe SSD : 8DV1RA13
Firmware for H101812SFSUN1.2T : A990
Firmware for H101860SFSUN600G : A990
Fortville plugin card firmware : 80001BBB
X540 LOM Firmware : 4.4

The fwupdate utility included with the Oracle Hardware Maintenance Pack can be used to update the HBA firmware. For example:

# cd Oracle_Server_X5-2-1.10.0.87089-FIRMWARE_PACK/Firmware/7101674/
# fwupdate update all -x metadata.xml

 

EMULEX ONECOMMAND MANAGER CLI

Download and install the latest firmware version for Oracle Sun Storage 16 Gb Fibre Channel PCIe Universal HBA from Emulex from the Oracle OEM section of the Avago Emulex Connectivity Division of Broadcom Limited website.

For example, for Solaris 11.2 or later:

% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:1A lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1A

Download Complete. Please reboot system to activate new firmware.
% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:1B lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1B

Download Complete. Please reboot system to activate new firmware.
% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:2A lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2A

Download Complete. Please reboot system to activate new firmware.
% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:2B lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2B

Download Complete. Please reboot system to activate new firmware.

Solaris 10, Solaris 11, and Solaris 11.1 require Emulex OneCommand Manager to be downloaded and installed as well in order to update the firmware. For example:

# /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:1A lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1A

Download Complete. Please reboot system to activate new firmware.
# /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:1B lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1B

Download Complete. Please reboot system to activate new firmware.
# /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:2A lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2A

Download Complete. Please reboot system to activate new firmware.
# /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:2B lancer_A10.6.230.0.grp

Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2B

Download Complete. Please reboot system to activate new firmware.

 

NOTE: A full power cycle reboot of the server is required to make the flash firmware version become the operational firmware version.

An example of where only a simple reboot was performed still shows the older version of firmware as the Operational FW:

% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd HbaAttributes 10:00:00:90:FA:87:65:1A

HBA Attributes for 10:00:00:90:FA:87:65:1A

Host Name : HOST
Manufacturer : Oracle Corporation
Serial Number : 4925382+1452000123
Model : 7101684
Model Desc : 7101684, Oracle 16GFC LP Universal HBA
Node WWN : 20 00 00 90 fa 87 65 1a
Node Symname : Emulex 7101684 FV1.1.60.2 DV3.0.05.0
HW Version : 0000000b
FW Version : 1.1.60.2
Vendor Spec ID : 10DF
Number of Ports : 1
Driver Name : emlxs
Driver Version : 3.0.05.0 (2015.09.16.13.00)
Device ID : E200
HBA Type : 7101684
Operational FW : 1.1.60.2
IEEE Address : 00 90 fa 87 65 1a
Boot Code : Enabled
Boot Version : 10.6.229.0
Board Temperature : Normal
Function Type : FC
Sub Device ID : E20E
PCI Bus Number : 0
PCI Func Number : 0
Sub Vendor ID : 10DF
IPL Filename : HL2RS2
Service Processor FW Name : 1.1.60.2
ULP FW Name : 1.1.60.2
FC Universal BIOS Version : 10.6.229.0
FC x86 BIOS Version : 10.6.229.0
FC EFI BIOS Version : 10.6.23.0
FC FCODE Version : 10.6.209.0
Flash Firmware Version : 10.6.230.0

If this fails to address the issue, please collect messages, fcinfo, as well as the Fibre Channel HBA attributes, port attributes, and physical media information..

% dmesg | grep emlxs
% sudo fcinfo hba-port
% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd HbaAttributes <WWPN>
% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd PortAttributes <WWPN>
% sudo /usr/lib/ssm/fwupdate/emulex/hbacmd GetXcvrData <WWPN>

 

References

<NOTE:1389639.1> - FAQ Oracle FC HBA: FCode/BIOS(ie. Boot Code), Firmware, and Drivers
<NOTE:1960235.1> - How To Verify Transceiver Type Installed In Oracle Sun Storage Branded Emulex 16Gb Fibre Channel / 10Gb FCoE Universal HBA On Solaris 11.2 And Later
<NOTE:1955822.1> - Solaris 11.2 (and later) FC HBA - Update Firmware, FCode/BIOS (ie. Boot Code)
<BUG:22835838> - PLZ. UPD. INSTALLATION GUIDE TO ENSURE THAT FULL POWER CYCLE FOLLOWS FW UPDATES.
<NOTE:1670748.1> - SFP Not Working In 16Gb FC HBA Emulex Card - WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected)

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback