Solution Type Problem Resolution Sure Solution 2119504.1 : emlxs WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) - FC HBA Firmware Upgrade Example
In this Document
Created from <SR 3-12241187781> Applies to:SPARC T5-2 - Version All Versions and laterEmulex FC HBA - Version All Versions and later Oracle Server X5-2 - Version All Versions and later SPARC T4-1 - Version All Versions and later SPARC T7-2 - Version All Versions and later Information in this document applies to any platform. SymptomsPhysical media (SFP+ Manufacturing Part Number 7023053) not detected by Oracle Sun Storage 16 Gb Fibre Channel PCIe Universal HBA from Emulex. For example: Feb 24 14:24:49 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs3: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off)
Feb 24 14:24:49 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs0: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs3: NOTICE: 730: Link reset. Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1B9F]emlxs3: NOTICE: 100: Driver attach. (Copyright (c) 2004-2014 Emulex. All rights reserved.) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LP10000-S: v1.92a1 (td192a1.all)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LP11000-S: v2.82a4 (bd282a4.all)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LP11002-S: v2.82a4 (bf282a4.all)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LPe11000-S: v2.82a4 (zd282a4.all)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LPe11002-S: v2.82a4 (zf282a4.all)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 6.0BC1]emlxs3: NOTICE:1502: Firmware Library (LPe12000-S: v2.01a12 (ud201a12.all)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs3: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs3: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs3: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs3: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs3: NOTICE: 100: Driver attach. (WWPN:10000090FA87652B WWNN:20000090FA87652B) Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs3 Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs3 Feb 24 14:24:51 HOST genunix: [ID 936769 kern.info] emlxs3 is /pci@0,0/pci8086,2f04@2/pci10df,e20e@0,1 Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs3 Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs3 Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs3:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs0: NOTICE: 730: Link reset. Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs0: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00)) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs0: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs0: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs0: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs0: NOTICE: 100: Driver attach. (WWPN:10000090FA87651A WWNN:20000090FA87651A) Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs0 Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs0 Feb 24 14:24:51 HOST genunix: [ID 936769 kern.info] emlxs0 is /pci@0,0/pci8086,2f02@1/pci10df,e20e@0 Feb 24 14:24:51 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs0 Feb 24 14:24:51 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs0 Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs2: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [14.0142]emlxs1: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) Feb 24 14:24:51 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs3: NOTICE: 730: Link reset. (Resetting link...) Feb 24 14:24:52 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs3: NOTICE: 730: Link reset. Feb 24 14:24:52 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs3:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs2: NOTICE: 730: Link reset. Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs2: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00)) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs2: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs2: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs2: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs2: NOTICE: 100: Driver attach. (WWPN:10000090FA87652A WWNN:20000090FA87652A) Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs2 Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs2 Feb 24 14:24:53 HOST genunix: [ID 936769 kern.info] emlxs2 is /pci@0,0/pci8086,2f04@2/pci10df,e20e@0 Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0, emlxs2 Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0, emlxs2 Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs2:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs2: NOTICE: 730: Link reset. (Resetting link...) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.05DA]emlxs1: NOTICE: 730: Link reset. Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA4]emlxs1: NOTICE: 100: Driver attach. (Emulex-S s11-64 i386 v3.0.05.0 (2015.09.16.13.00)) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BA7]emlxs1: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BAE]emlxs1: NOTICE: 100: Driver attach. (Firmware:%R:IP4% (xe201.grp) Boot:%R:IP4%) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BDE]emlxs1: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ B.1BEC]emlxs1: NOTICE: 100: Driver attach. (WWPN:10000090FA87651B WWNN:20000090FA87651B) Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs1 Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs1 Feb 24 14:24:53 HOST genunix: [ID 936769 kern.info] emlxs1 is /pci@0,0/pci8086,2f02@1/pci10df,e20e@0,1 Feb 24 14:24:53 HOST pcieb: [ID 586369 kern.info] PCIE-device: pci10df,e20e@0,1, emlxs1 Feb 24 14:24:53 HOST npe: [ID 236367 kern.info] PCI Express-device: pci10df,e20e@0,1, emlxs1 Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs1: NOTICE: 730: Link reset. (Resetting link...) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs0: NOTICE: 730: Link reset. (Resetting link...) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs2: NOTICE: 730: Link reset. Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs2:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs1: NOTICE: 730: Link reset. Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [ 5.073F]emlxs0: NOTICE: 730: Link reset. Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Feb 24 14:24:53 HOST emlxs: [ID 349649 kern.info] [14.14E0]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected)
ChangesInitially, the Oracle Sun Storage 16 Gb Fibre Channel PCIe Universal HBA from Emulex only shipped with and supported Fibre Channel Physical Media Optic Emulex Part Number AFBR-57F5MZ-ELX. % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd GetXcvrData 10:00:00:90:fa:2e:e1:82
VendorName: EMULEX VendorOui: 00-17-6a VendorPN: AFBR-57F5MZ-ELX VendorRev: VendorSN: AA1209J02L2 DateCode: 120302 Identifier: 3h ExtIdentifier: 4h Connector: 7h Wavelength: 850 nm Temperature: 37.73 C Vcc: 3.31 V TxBiasCurrent: 7.43 mA TxPower: 0.58 mW RxPower: 0.46 mW Avago Emulex Connectivity Division of Broadcom Limited added support for Fibre Channel Physical Media Optic FINISAR CORPORATION Part Number FTLF8529P3BCV-EM in firmware version 10.6.230.0. % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd GetXcvrData 10:00:00:90:FA:87:65:1A
VendorName: FINISAR CORP. VendorOui: 00-90-65 VendorPN: FTLF8529P3BCV-EM VendorRev: B VendorSN: USL0Q6B DateCode: 141116 Identifier: 3h ExtIdentifier: 4h Connector: 7h Wavelength: 850 nm Temperature: 44.64 C Vcc: 3.41 V TxBiasCurrent: 0.00 mA TxPower: 0.00 mW RxPower: 0.54 mW
NOTE: TxPower is 0.00 mW when unsupported physical media is installed.
CauseA minimum of firmware version 10.6.230.0 is required to support FINISAR CORPORATION Part Numbers FTLF8529P3BCV-EM and FTLX8571D3BCL-EM. In summary, the supported Fibre Channel optics: VENDOR_OUI_FINISAR VENDOR_OUI_AVAGO The supported Ethernet optics: VENDOR_OUI_FINISAR VENDOR_OUI_AVAGO SolutionFIRMWARE PACK As an alternative to the Multi-Boot Image Update Kit on the Oracle OEM portion of the Broadcom Emulex Connectivity Division (ECD) website, some platforms now offer a firmware pack. For example, Patch 26413467 Oracle Server X5-2 SW 1.10.0 - FIRMWARE PACK also now includes updated firmware for the platform as well as Fibre Channel and SAS HBAs, disk, etc. Oracle Server X5-2 Software Release: 1.10.0.87089 Firmware The fwupdate utility included with the Oracle Hardware Maintenance Pack can be used to update the HBA firmware. For example: # cd Oracle_Server_X5-2-1.10.0.87089-FIRMWARE_PACK/Firmware/7101674/
# fwupdate update all -x metadata.xml
EMULEX ONECOMMAND MANAGER CLI Download and install the latest firmware version for Oracle Sun Storage 16 Gb Fibre Channel PCIe Universal HBA from Emulex from the Oracle OEM section of the Avago Emulex Connectivity Division of Broadcom Limited website. For example, for Solaris 11.2 or later: % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:1A lancer_A10.6.230.0.grp
Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1A Download Complete. Please reboot system to activate new firmware. % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:1B lancer_A10.6.230.0.grp Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1B Download Complete. Please reboot system to activate new firmware. % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:2A lancer_A10.6.230.0.grp Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2A Download Complete. Please reboot system to activate new firmware. % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd download 10:00:00:90:FA:87:65:2B lancer_A10.6.230.0.grp Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2B Download Complete. Please reboot system to activate new firmware. Solaris 10, Solaris 11, and Solaris 11.1 require Emulex OneCommand Manager to be downloaded and installed as well in order to update the firmware. For example: # /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:1A lancer_A10.6.230.0.grp
Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1A Download Complete. Please reboot system to activate new firmware. # /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:1B lancer_A10.6.230.0.grp Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:1B Download Complete. Please reboot system to activate new firmware. # /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:2A lancer_A10.6.230.0.grp Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2A Download Complete. Please reboot system to activate new firmware. # /opt/ELXocm/hbacmd download 10:00:00:90:FA:87:65:2B lancer_A10.6.230.0.grp Downloading lancer_A10.6.230.0.grp to hba 10:00:00:90:FA:87:65:2B Download Complete. Please reboot system to activate new firmware.
NOTE: A full power cycle reboot of the server is required to make the flash firmware version become the operational firmware version.
An example of where only a simple reboot was performed still shows the older version of firmware as the Operational FW: % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd HbaAttributes 10:00:00:90:FA:87:65:1A
HBA Attributes for 10:00:00:90:FA:87:65:1A Host Name : HOST Manufacturer : Oracle Corporation Serial Number : 4925382+1452000123 Model : 7101684 Model Desc : 7101684, Oracle 16GFC LP Universal HBA Node WWN : 20 00 00 90 fa 87 65 1a Node Symname : Emulex 7101684 FV1.1.60.2 DV3.0.05.0 HW Version : 0000000b FW Version : 1.1.60.2 Vendor Spec ID : 10DF Number of Ports : 1 Driver Name : emlxs Driver Version : 3.0.05.0 (2015.09.16.13.00) Device ID : E200 HBA Type : 7101684 Operational FW : 1.1.60.2 IEEE Address : 00 90 fa 87 65 1a Boot Code : Enabled Boot Version : 10.6.229.0 Board Temperature : Normal Function Type : FC Sub Device ID : E20E PCI Bus Number : 0 PCI Func Number : 0 Sub Vendor ID : 10DF IPL Filename : HL2RS2 Service Processor FW Name : 1.1.60.2 ULP FW Name : 1.1.60.2 FC Universal BIOS Version : 10.6.229.0 FC x86 BIOS Version : 10.6.229.0 FC EFI BIOS Version : 10.6.23.0 FC FCODE Version : 10.6.209.0 Flash Firmware Version : 10.6.230.0 If this fails to address the issue, please collect messages, fcinfo, as well as the Fibre Channel HBA attributes, port attributes, and physical media information.. % dmesg | grep emlxs
% sudo fcinfo hba-port % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd HbaAttributes <WWPN> % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd PortAttributes <WWPN> % sudo /usr/lib/ssm/fwupdate/emulex/hbacmd GetXcvrData <WWPN>
References<NOTE:1389639.1> - FAQ Oracle FC HBA: FCode/BIOS(ie. Boot Code), Firmware, and Drivers<NOTE:1960235.1> - How To Verify Transceiver Type Installed In Oracle Sun Storage Branded Emulex 16Gb Fibre Channel / 10Gb FCoE Universal HBA On Solaris 11.2 And Later <NOTE:1955822.1> - Solaris 11.2 (and later) FC HBA - Update Firmware, FCode/BIOS (ie. Boot Code) <BUG:22835838> - PLZ. UPD. INSTALLATION GUIDE TO ENSURE THAT FULL POWER CYCLE FOLLOWS FW UPDATES. <NOTE:1670748.1> - SFP Not Working In 16Gb FC HBA Emulex Card - WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) Attachments This solution has no attachment |
||||||||||||||||||||
|