Solution Type Problem Resolution Sure Solution 1567869.1 : SPARC T5-2 : After multiple coin battery replacement the server still reports SPT-8000-G3 (fault.chassis.battery.fail)
Despite replacing the coin battery on the motherboard of a SPARC T5-2 server, the ILOM fault management shell still reports the battery as faulty (fault.chassis.battery.fail) In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:SPARC T5-2 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsAfter replacing the Coin Battery ( 371-2210 [C] 3V Lithium Coin Cell Battery ) and clearing the error messages under the ILOM Fault Management shell multiple times the ILOM persistently still reports the battery is faulty ( MSGID SPT-8000-G3 ). -> start /SP/faultmgmt/shell/ Are you sure you want to start /SP/faultmgmt/shell (y/n)? y faultmgmtsp> fmdump TIMESTAMP UUID MSGID 2000-01-01/00:03:13 31f10a21-0003-c2d2-a4fc-ee9104946253 SPT-8000-G3 2000-01-01/00:03:39 f151b0a3-6f8f-e1fd-fa14-c2ae503933f0 SPT-8000-G3 2000-01-01/00:03:35 36365288-7209-6c62-ffc7-ce7ea6a0ae04 SPT-8000-G3 2013-06-26/19:08:18 1f556ca9-ab2c-64f7-fff7-d280e540808a SPT-8000-G3 2013-06-26/19:18:45 86343237-6f2a-4930-e736-8a0fed052de3 SPT-8000-G3 2013-06-27/07:13:08 6a741968-f183-4c2b-c67b-b08b31333a87 SPT-8000-G3 2013-06-27/07:20:58 2a1a8a69-532f-437d-d82c-eafbca7272eb SPT-8000-G3 2013-06-27/07:21:23 6860eb65-fabf-c681-a098-8713676aa73f SPT-8000-G3 2013-06-27/07:21:59 0136cd4f-a437-e88c-9949-feca22f78247 SPT-8000-G3 2000-01-01/00:03:31 b832957e-5514-41c1-e3b5-9254db0ab733 SPT-8000-G3 2013-06-27/19:46:08 acef8ef3-e2da-6efb-e5d2-c91b7bd2b6df SPT-8000-G3 2013-06-27/19:47:31 ba57b088-1f2c-e18b-da43-f39a6801c38e SPT-8000-G3 2013-06-27/19:54:38 1d79f9d0-c6d0-4b0a-b8cb-ed848e47168f SPT-8000-G3 2013-06-27/19:54:54 27740e8a-53d9-4e93-f087-9fe63ff66363 SPT-8000-G3 2013-06-27/19:55:16 61265a3b-aee6-ef37-dd13-f041cd02d1b3 SPT-8000-G3 2013-06-27/19:59:57 3af7cdc4-1941-c80e-ba10-852ce6301043 SPT-8000-G3 2013-06-27/20:08:54 d3d39b1d-4b00-448d-879e-ca3faad21481 SPT-8000-G3 2013-06-27/20:10:19 f1e428ab-143c-ee3e-e987-dbcd40ddc183 SPT-8000-G3 2013-06-27/20:10:30 a9d4276f-3b5c-c84b-9dfa-b53be2323c34 SPT-8000-G3 2013-06-27/20:10:40 04e0f080-f121-ccb2-dd74-a4217881a767 SPT-8000-G3 faultmgmtsp> fmadm faulty ------------------- ------------------------------------ -------------- -------- Time UUID msgid Severity ------------------- ------------------------------------ -------------- -------- 2013-06-27/20:10:40 04e0f080-f121-ccb2-dd74-a4217881a767 SPT-8000-G3 Minor Problem Status : solved Diag Engine : fdd 1.0 System Manufacturer : Oracle Corporation Name : SPARC T5-2 Part_Number : 31834814+3+1 Serial_Number : AK00105979 ---------------------------------------- Suspect 1 of 1 Fault class : fault.chassis.battery.fail Certainty : 100% Affects : /SYS Status : faulted but still in service FRU Status : faulty Location : /SYS/MB/BAT Chassis Manufacturer : Oracle Corporation Name : SPARC T5-2 Part_Number : 31834814+3+1 Serial_Number : AK00105979 Description : The real-time-clock backup battery is approaching the end of its lifetime. Response : The chassis-wide service required LED will be illuminated. Impact : ILOM and/or Host time of day may not be retained when power is lost. Action : Please refer to the associated reference document at http://support.oracle.com/msg/SPT-8000-G3 for the latest service procedures and policies regarding this diagnosis. faultmgmtsp> ILOM initial power up also reports the following error from the serial console: <DIAGS> PHY #0 R/W Test ... PASSED <DIAGS> PHY #0 Link Status ... PASSED Setting 100 BASE-X Setting full duplex mode. Mac Addr is 0 10 e0 35 9e c1 <DIAGS> ETHERNET PHY #0, Internal Loopback Test ... |/ PASSED <DIAGS> Testing RTC ..... 0%33%66% PASSED ERROR: Voltage Check: MEZZ V_bat is under voltage. Target(3.00V, 2.55V, 3.30V) Actual(.96V) <DIAGS> VOLTAGE SENSOR Test ... FAILED Writing sppost console log to flash Un-Protected 4 sectors Erasing .... done Erased 4 sectors Writing done
CauseIf errors continue after replacing the Coin Battery and clearing error messages (under ILOM Fault Management shell) multiple times (2 or more) the following troubleshooting steps need to be completed: 1.) Reseat the ILOM Service Processor (SP) and clear the error messages under the ILOM Fault Management shell: 2.) Replace the ILOM Service Processor (SP) and clear the error messages under the ILOM Fault Management shell: 3.) Replace T5-2 Motherboard (MB) as last resort and clear the error messages under the ILOM Fault Management shell: Note: This SPARC T5-2 server Coin Battery failure was caused by a faulty ILOM Service Processor. SolutionThis issue can be fixed by following the above 3 troubleshooting steps (in order) after replacing the Coin Battery multiple times (2 or more). References<NOTE:1905981.1> - Solaris may fail to boot after replacing system battery on a SPARC T4-x/T5-x serversAttachments This solution has no attachment |
||||||||||||||||||
|