Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1567869.1
Update Date:2017-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1567869.1 :   SPARC T5-2 : After multiple coin battery replacement the server still reports SPT-8000-G3 (fault.chassis.battery.fail)  


Related Items
  • SPARC T5-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  


Despite replacing the coin battery on the motherboard of a SPARC T5-2 server, the ILOM  fault management shell still reports the battery as faulty (fault.chassis.battery.fail)

In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: This is useful for troubleshooting battery issues on SPARC T5-2
Created from <SR 3-7443079681>

Applies to:

SPARC T5-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After replacing the Coin Battery ( 371-2210 [C] 3V Lithium Coin Cell Battery ) and clearing the error messages under the ILOM Fault Management shell multiple times the ILOM persistently 
still reports the battery is faulty ( MSGID SPT-8000-G3 ). 

  -> start /SP/faultmgmt/shell/
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp> fmdump
TIMESTAMP            UUID                                   MSGID
2000-01-01/00:03:13  31f10a21-0003-c2d2-a4fc-ee9104946253   SPT-8000-G3
2000-01-01/00:03:39  f151b0a3-6f8f-e1fd-fa14-c2ae503933f0   SPT-8000-G3
2000-01-01/00:03:35  36365288-7209-6c62-ffc7-ce7ea6a0ae04   SPT-8000-G3
2013-06-26/19:08:18  1f556ca9-ab2c-64f7-fff7-d280e540808a   SPT-8000-G3
2013-06-26/19:18:45  86343237-6f2a-4930-e736-8a0fed052de3   SPT-8000-G3
2013-06-27/07:13:08  6a741968-f183-4c2b-c67b-b08b31333a87   SPT-8000-G3
2013-06-27/07:20:58  2a1a8a69-532f-437d-d82c-eafbca7272eb   SPT-8000-G3
2013-06-27/07:21:23  6860eb65-fabf-c681-a098-8713676aa73f   SPT-8000-G3
2013-06-27/07:21:59  0136cd4f-a437-e88c-9949-feca22f78247   SPT-8000-G3
2000-01-01/00:03:31  b832957e-5514-41c1-e3b5-9254db0ab733   SPT-8000-G3
2013-06-27/19:46:08  acef8ef3-e2da-6efb-e5d2-c91b7bd2b6df   SPT-8000-G3
2013-06-27/19:47:31  ba57b088-1f2c-e18b-da43-f39a6801c38e   SPT-8000-G3
2013-06-27/19:54:38  1d79f9d0-c6d0-4b0a-b8cb-ed848e47168f   SPT-8000-G3
2013-06-27/19:54:54  27740e8a-53d9-4e93-f087-9fe63ff66363   SPT-8000-G3
2013-06-27/19:55:16  61265a3b-aee6-ef37-dd13-f041cd02d1b3   SPT-8000-G3
2013-06-27/19:59:57  3af7cdc4-1941-c80e-ba10-852ce6301043   SPT-8000-G3
2013-06-27/20:08:54  d3d39b1d-4b00-448d-879e-ca3faad21481   SPT-8000-G3
2013-06-27/20:10:19  f1e428ab-143c-ee3e-e987-dbcd40ddc183   SPT-8000-G3
2013-06-27/20:10:30  a9d4276f-3b5c-c84b-9dfa-b53be2323c34   SPT-8000-G3
2013-06-27/20:10:40  04e0f080-f121-ccb2-dd74-a4217881a767   SPT-8000-G3


faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- --------
Time                UUID                                 msgid          Severity
------------------- ------------------------------------ -------------- --------
2013-06-27/20:10:40 04e0f080-f121-ccb2-dd74-a4217881a767 SPT-8000-G3    Minor

Problem Status    : solved
Diag Engine       : fdd 1.0
System
   Manufacturer   : Oracle Corporation
   Name           : SPARC T5-2
   Part_Number    : 31834814+3+1
   Serial_Number  : AK00105979

----------------------------------------
Suspect 1 of 1
   Fault class  : fault.chassis.battery.fail
   Certainty    : 100%
   Affects      : /SYS
   Status       : faulted but still in service

   FRU
      Status            : faulty
      Location          : /SYS/MB/BAT
      Chassis
         Manufacturer   : Oracle Corporation
         Name           : SPARC T5-2
         Part_Number    : 31834814+3+1
         Serial_Number  : AK00105979

Description : The real-time-clock backup battery is approaching the end of
              its lifetime.

Response    : The chassis-wide service required LED will be illuminated.

Impact      : ILOM and/or Host time of day may not be retained when power
              is lost.

Action      : Please refer to the associated reference document at
              http://support.oracle.com/msg/SPT-8000-G3 for the latest
              service procedures and policies regarding this diagnosis.

faultmgmtsp>



ILOM initial power up also reports the following error from the serial console:
<DIAGS> PHY #0 R/W Test ... PASSED
<DIAGS> PHY #0 Link Status ... PASSED
Setting 100 BASE-X
Setting full duplex mode.
Mac Addr is 0 10 e0 35 9e c1
<DIAGS> ETHERNET PHY #0, Internal Loopback Test ... |/ PASSED 
<DIAGS> Testing RTC .....  0%33%66% PASSED 
ERROR: Voltage Check: MEZZ V_bat is under voltage. Target(3.00V, 2.55V, 3.30V) Actual(.96V)
<DIAGS> VOLTAGE SENSOR Test ... FAILED
Writing sppost console log to flash
Un-Protected 4 sectors
Erasing 
.... done
Erased 4 sectors
Writing 
done

 

 

Cause

If errors continue after replacing the Coin Battery and clearing error messages (under ILOM Fault Management shell) multiple times (2 or more) the following troubleshooting steps need to be completed:

1.) Reseat the ILOM Service Processor (SP) and clear the error messages under the ILOM Fault Management shell:
     a.) Reseat Service Processor (SP)
     b.) faultmgmtsp> fmadm repaired /SYS/SP
     c.) Set Date/Time under ILOM (--> set /SP/clock datetime=MMDDhhmmYYYY.ss)
     d.) Reset SP (--> reset /SP) and check for errors under Fault Management shell (faultmgmtsp> fmadm faulty)
     e.) If still seeing error messages under the Fault Management shell (faultmgmtsp> fmadm faulty) got to Step #2

2.) Replace the ILOM Service Processor (SP) and clear the error messages under the ILOM Fault Management shell:
     a.) Replace Service Processor (SP)
     b.) faultmgmtsp> fmadm replaced /SYS/SP
     c.) Set Date/Time under ILOM (--> set /SP/clock datetime=MMDDhhmmYYYY.ss)
     d.) Reset SP (--> reset /SP) and check for errors under Fault Management shell (faultmgmtsp> fmadm faulty)
     c.) If still seeing error messages under the Fault Management shell (faultmgmtsp> fmadm faulty) got to Step #3

3.) Replace T5-2 Motherboard (MB) as last resort and clear the error messages under the ILOM Fault Management shell:
     a.) Replace Motherboard (MB)
     b.) faultmgmtsp> fmadm replaced /SYS/MB
     c.) Set Date/Time under ILOM (--> set /SP/clock datetime=MMDDhhmmYYYY.ss)
     d.) Reset SP (--> reset /SP) and check for errors under Fault Management shell (faultmgmtsp> fmadm faulty)

Note: This SPARC T5-2 server Coin Battery failure was caused by a faulty ILOM Service Processor.

Solution

This issue can be fixed by following the above 3 troubleshooting steps (in order) after replacing the Coin Battery multiple times (2 or more).

References

<NOTE:1905981.1> - Solaris may fail to boot after replacing system battery on a SPARC T4-x/T5-x servers