Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1613206.1
Update Date:2017-05-09
Keywords:

Solution Type  Problem Resolution Sure

Solution  1613206.1 :   SPARC T5-X at System Firmware 9.1.1 Downgrade or Re-flash firmware using BUI method may fail.  


Related Items
  • SPARC T5-8
  •  
  • SPARC T5-4
  •  
  • SPARC T5-2
  •  
  • SPARC T5-1B
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

SPARC T5-1B - Version All Versions and later
SPARC T5-8 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
SPARC T5-2 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Using BUI method to re-flash or downgrade firmware on SPARC T5-X servers with System Firmware 9.1.1 may experience hang and will not complete.

Occurs during the upload firmware step.  The firmware upload process will appear hung and may timeout.

Cause

ILOM software regression.  Issue only seen with System Firmware 9.1.1

 

This is related to bug 17816477

Solution

Upgrade to 9.1.2.D or greater, or use the CLI load command as documented in

Oracle Integrated Lights Out Manager (ILOM) Documentation Collection for Firmware Release 3.2

> load -source protocol://username:password@server_ip/<path_to_image>/<image.pkg>

The fix for Bug 17816477 will be in SysFW 9.1.2


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.