![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1613206.1 : SPARC T5-X at System Firmware 9.1.1 Downgrade or Re-flash firmware using BUI method may fail.
In this Document
Applies to:SPARC T5-1B - Version All Versions and laterSPARC T5-8 - Version All Versions and later SPARC T5-4 - Version All Versions and later SPARC T5-2 - Version All Versions and later Information in this document applies to any platform. SymptomsUsing BUI method to re-flash or downgrade firmware on SPARC T5-X servers with System Firmware 9.1.1 may experience hang and will not complete. Occurs during the upload firmware step. The firmware upload process will appear hung and may timeout. CauseILOM software regression. Issue only seen with System Firmware 9.1.1
This is related to bug 17816477 SolutionUpgrade to 9.1.2.D or greater, or use the CLI load command as documented in Oracle Integrated Lights Out Manager (ILOM) Documentation Collection for Firmware Release 3.2 > load -source protocol://username:password@server_ip/<path_to_image>/<image.pkg> The fix for Bug 17816477 will be in SysFW 9.1.2 Attachments This solution has no attachment |
||||||||||||||||
|