![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2021743.1 : T5-x ILOM reports spurious V_IN_WARN asserted / deasserted events
Applies to:SPARC T5-2 - Version All Versions and laterInformation in this document applies to any platform. SymptomsThe following PSU sensor assertion/deassertion events occur often with roughly 5 second separation: Jun 4 14:49:24 t5domaina-00 SC Alert: [ID 309697 daemon.notice] Sensor | CauseThe sensor is incorrectly triggering a Warning message. SolutionPlease ignore the V_IN_WARN events listed above since they are benign. In many cases, the customer has supplied input voltage below the certified level. This sensor's threshold crossing was changed from a warming to an informational message in system firmware version 9.5, ILOM version 3.2.5.6. Systems with firmware version 9.5 or newer will now report V_IN_INFO events which can typically be ignored. Attachments This solution has no attachment |
||||||||||||
|