Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1586490.1
Update Date:2018-01-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1586490.1 :   Unable To configure ILOM Net MGMT port - Unable to get network management property  


Related Items
  • SPARC T5-8
  •  
  • SPARC T5-4
  •  
  • SPARC T5-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




Created from <SR 3-7848704254>

Applies to:

SPARC T5-4 - Version All Versions and later
SPARC T5-2 - Version All Versions and later
SPARC T5-8 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The user is unable to set the ILOM's Net Mgmt parameters:

-> set pendingipdiscovery=static
Set 'pendingipdiscovery' to 'static'

-> set pendingipaddress=10.175.193.43
Set 'pendingipaddress' to '10.175.193.43'

-> set pendingipnetmask=255.255.254.0
Set 'pendingipnetmask' to '255.255.254.0'

-> set pendingipgateway=10.175.192.1
Set 'pendingipgateway' to '10.175.192.1'

-> set /SP hostname=up06814-ilom
Set 'hostname' to 'up06814-ilom'

-> set commitpending=true
set: Unable to get network management property

Cause

If the ILOM's network management cable is not connected to the network, then this problem can occur.

This is related to bug 15990899

Solution

The network parameters can be configured once the Net MGMT cable is connected to the network.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.