![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1915487.1 : HV Abort on guest domain shutdown
In this Document
Created from <SR 3-8940138131> Applies to:SPARC T5-2 - Version All Versions to All Versions [Release All Releases]SPARC T5-4 - Version All Versions to All Versions [Release All Releases] SPARC T5-8 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsWhen stopping or migrating an Oracle VM guest domain using ldm the system suffers a Hypervisor Abort, impacting the entire chassis. The following is reported in ILOM event logs after issuing the ldm stop or migration request; 684 Tue May 6 10:32:13 2014 System Log minor A manual power cycle is required to recover the system. All guest domains may not be exposed to this issue, however once a domain experiences this behavior the symptoms will remain persistent on shutdown/migration operations. Causetick_sync is enabled in SPARC T5 SysFW as per bug 18724928. SolutionSysFW 9.3.0.b resolves this problem. References<BUG:18724928> - PIO/HV ABORT ON GUEST DOMAIN SHUTDOWN : T5Attachments This solution has no attachment |
||||||||||||||||||
|