Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1915487.1
Update Date:2017-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1915487.1 :   HV Abort on guest domain shutdown  


Related Items
  • SPARC T5-4
  •  
  • SPARC T5-2
  •  
  • SPARC T5-8
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8940138131>

Applies to:

SPARC T5-2 - Version All Versions to All Versions [Release All Releases]
SPARC T5-4 - Version All Versions to All Versions [Release All Releases]
SPARC T5-8 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

When stopping or migrating an Oracle VM guest domain using ldm the system suffers a Hypervisor Abort, impacting the entire chassis.

The following is reported in ILOM event logs after issuing the ldm stop or migration request;

684 Tue May 6 10:32:13 2014 System Log minor
      Host: Standby
683 Tue May 6 10:32:13 2014 System Log minor
      Host: Error Standby
682 Tue May 6 10:31:45 2014 System Log minor
      Host: Solaris panicking
681 Tue May 6 10:31:44 2014 System Log minor
      May 6 10:31:44 ERROR: HV Abort: PC = 0xb721eec

A manual power cycle is required to recover the system.

All guest domains may not be exposed to this issue, however once a domain experiences this behavior the symptoms will remain persistent on shutdown/migration operations. 

Cause

tick_sync is enabled in SPARC T5 SysFW as per bug 18724928.
 

Solution

SysFW 9.3.0.b resolves this problem.

References

<BUG:18724928> - PIO/HV ABORT ON GUEST DOMAIN SHUTDOWN : T5