Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek VSM4 System : Problem Documents


Problem Document Synopsis Last Modified Date
2338650.1 VSM - How to reset or switch the ISP master due to no Detached Operator's Panel (DOP) and/or vshell access 2017-12-13
2291723.1 VSM4/VSM5 - FSC7596--Check0 (CK0) Warmboot Completed Successfully 2017-08-14
2169430.1 VSM - HDA (Disk Drive) Ready LED not lit. 2016-08-05
2118259.1 D/H02.20.03.00 microcode Potential Data Integrity problem if using FASTRECL 2016-03-18
2083456.1 Potential FSC3BBB warmboots after upgrading from D02.15.xx.00 code if the VSM4 has Escon host connections 2015-12-15
1940570.1 CTR Replication On CLINK Hung or Slow Migrations 2017-10-09
1927077.1 SDP2 - VSM Discover Failure: "Unable to gather device info" 2016-04-03
1680677.1 Prerequisite Brocade firmware for D/H02.18 and higher microcode 2014-12-22
1662904.1 Potential FSC3BBB Warm Boots after upgrading from D/H02.17 code. 2016-06-30
1635005.1 VSM - SLS6662E & SLS6625E messages on 9840C Tape Drive on different tapes 2018-03-06
1623273.1 Shared RTD Vary Path Command takes RTD Offline 2014-02-11
1619684.1 FSC3BBB warm boots, 613-08, 813-04 or A13-10 Abends via VTD0 of VSM 2014-02-03
1580257.1 VSM/SVA - SIM Alert or Serious Alert with FSCF305 2017-11-15
1569194.1 VSM: T10000 Tape Drive Failed to Initialize New MVC Media Using ALP 2013-07-23
1560748.1 VSM - Cannot clear or GFR no replace a fenced PDU 2015-08-04
1548756.1 VSM - RTDs Will Not Vary Online Though Path Validation Successful: RTD FSCFF00 2016-02-02
1537747.1 NDCL Code Upgrade Limitation due to NED change 2013-03-18
1526191.1 Canceling A Job May Leave A VTV Mounted if FASTRECL=YES is Specified 2016-06-23
1519610.1 ASR opens a Service Request with FCS Code 7358 2018-01-10
1513428.1 SLS6625E RTD dddddddd Reported Volume Fenced 2018-02-23
1484846.1 VSM - ECAM I/O error RC=6A40FF14 2018-01-04
1475876.1 VSM posting FSC73E1 while staging microcode from VIP floppy. 2018-01-10
1460028.1 VSM - VTSS event log filliing up with FSCD0A0 and FSCD123 2018-01-10
1457121.1 VSM4 - FSC 32CB received indicating recoverable ESCON channel errors 2018-05-01
1447831.1 VSM - SLS6684I with ECAM error of CC=09 RC=143 2018-01-10
1446831.1 VSM - Repeated FSC3A46 Warm Boots after Power Up 2018-01-10
1444608.1 VSM - FSC3BC8 and FSC8E4B Warm Boots with Possible Data Corruption 2015-07-19
1382823.1 VSM/SVA - ASR or MIM For FSC73F8 (ISP hard Drive Nearly Full) 2017-03-22
1371320.1 VSM - IBM z/OS 1.12 and 1.13 May Cause FSC3BC8 Warm Boots Under High Workload 2016-02-02
1365265.1 VSM - z/OS Host Messages IOS000I / IOS102I / SLS6698I / SLS5079E 2016-06-23
1363752.1 VSM - How to identify FRU for FSC7E92 or FSC7E93, Power Supply error 2018-03-21
1356932.1 VSM/SVA - FSC7359 SIM Alert 2018-05-07
1338829.1 VSM - SMF251 Channel Name Field is missing 2017-03-20
1332413.1 VSM - FSC3E41 & FSC3E42 Production Partition Conditional Capacity Low Threshold Reached 2016-08-26
1332389.1 FSC3E40 Subsystem is out of Conditional Capacity 2018-05-24
1332371.1 VSM - Performance issues with certain long chain jobs 2018-01-08
1328980.1 VSM - Fenced AVM card due to FSCF40A 2017-03-20
1326126.1 VSM - Event log filling up with FSC88A5 and FSC88A6 on one channel 2017-03-20
1320556.1 VSM - Channel Card Reporting FSC32C0 Parity Errors 2017-03-20
1317325.1 VSM - SLS6659I SIM error with FSC7596 2016-02-02
1316184.1 VSM - Warmboot FSC7596 with 3BC8 in sense bytes 30,31 of SIM message 2018-01-08
1312147.1 VSM - FSC3931 VCF4 card failure on VSM5 causes cluster outage 2013-06-03
1310923.1 VSM - VCF card failed with FSC 3659 followed by FSC 38BE Warm Boot Recovery 2018-02-03
1309987.1 VSM / SVA - Failed Disk Drive - HDA - FSC Fault Symptom Code 2018-01-23
1290862.1 VSM - MIM request not beng processed, FSC7351 being logged 2018-01-08
1284809.1 VSM DFSMSdss Restore Failure with IBM ADR351E ADR370E ADR373E ADR789W 2018-01-08
1146537.1 VSM--VTV written at the time of check0 results in permanent data check 2017-03-20
1119554.1 VSM - FSC73D8 RTD is Offline 2016-06-23
1021032.1 VSM Channel Detected Errors when using "Short Reads" and SLI /LBI 2018-02-13
1019755.1 VSM - The VTCS Display VTSS command shows a VTSS is Online-P 2017-07-21
1018379.1 VSM - RTD not configured 2018-05-03
1017197.1 Message SLS6684I Reports Error code CC=08 RC=120 and VTSS is at Capacity 2018-04-02
1016754.1 VSM/SVA - FSC79A5 - pfaelg4a.dat overflow due to High Volume of FSC3FFA errors 2012-06-04
1016751.1 VTV Migrates and Recalls time out - SLS6684I with ECAM ERROR CC=5 RC=112 2017-09-29
1016507.1 VSM - z/OS Host Messages IOS000I / IOS071I / SLS6698I 2017-07-27
1016471.1 VSM - VTSS fails to initialize after SLS6675E with RC=xxxxxx0C 2018-01-08
1016322.1 VSM - Fails to Initialize during HSC/VTCS start-up after SLS6675E with RC=08 2018-01-08
1015173.1 Message SLS5024E Timeout on ECAM I/O to Device 2018-04-02
1015151.1 VSM - Message SLS5079E mount failed CC=9 RC =146 2017-03-10
1015009.1 When Migrating a VTSS to Threshold (0) the DBU Does Not Drop to 0.0% 2015-06-24
1014805.1 VSM - MVCs Incorrectly Identified As Expired 2011-06-14
1014359.1 VSM - Message SLS6675E Configuration Error RC=00000004 - VTSS Name On Box Does Not Match CONFIG 2016-06-23
1014137.1 VSM - SLS6684I Ecam Error CC=09 RC=30 2018-01-08
1013826.1 VSM - Message SLS6675E Configuration Error RC=00000004 after Changing VTD Device Addresses 2016-01-25
1013691.1 VSM - RTDs Remain Online After The VTSS Has Been Varied Offline 2016-08-16
1013355.1 VSM - Some MVCs stay in Draining Status after Reclaim. 2018-01-08
1013209.1 Message SLS6645I VTSS is 99% Full - Host Listed in SLS6703I is Not Active 2015-05-07
1013050.1 VSM - SLS6743E VTSS VTSSxxx FOUND IN INCONSISTENT STATE 2010-02-11
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.