Solution Type  Problem Resolution Sure

Solution  1013209.1 :   Message SLS6645I VTSS is 99% Full - Host Listed in SLS6703I is Not Active  


Related Items
  • Sun StorageTek Virtual Tape Control Software (VTCS)
  •  
  • Sun StorageTek Enterprise Library Software (ELS)
  •  
  • Sun StorageTek VSM System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Library Software>SN-TP: MAINSW VTCS
  •  

PreviouslyPublishedAs
218282


Applies to:

Sun StorageTek Virtual Tape Control Software (VTCS) - Version 6.2 and later
Sun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later
Sun StorageTek VSM System - Version 4 and later
IBM z/OS on System z

Symptoms

SLS6645I VTSS is 99% full
SLS6703I Host HHHH is performing AUTO MIGRATION to target N% on VTSS XXXXXXXX
HSC is not active on the host listed in the SLS6703I message.

Cause

Although message SLS6703I indicates auto migration is actively running on another host, auto migration is not actually running because that HSC is down. 

A host that becomes inoperable while resources are being used makes those resources unavailable to any other host.  This can happen when HSC is canceled and not allowed to come down clean.

Solution

Issue the HSC command to recover AUTO MIGRATION. Example follows:

RECover host-id

For complete information on using the RECover command, please see the ELS Command, Control Statement, and Utility Reference.  Instructions for downloading current manuals are available in <Document 1014318.1>.