![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1013209.1 : Message SLS6645I VTSS is 99% Full - Host Listed in SLS6703I is Not Active
PreviouslyPublishedAs 218282 Applies to:Sun StorageTek Virtual Tape Control Software (VTCS) - Version 6.2 and laterSun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later Sun StorageTek VSM System - Version 4 and later IBM z/OS on System z SymptomsSLS6645I VTSS is 99% full CauseAlthough message SLS6703I indicates auto migration is actively running on another host, auto migration is not actually running because that HSC is down. A host that becomes inoperable while resources are being used makes those resources unavailable to any other host. This can happen when HSC is canceled and not allowed to come down clean. SolutionIssue the HSC command to recover AUTO MIGRATION. Example follows:
For complete information on using the RECover command, please see the ELS Command, Control Statement, and Utility Reference. Instructions for downloading current manuals are available in <Document 1014318.1>. Attachments This solution has no attachment |
||||||||||||
|