![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1332413.1 : VSM - FSC3E41 & FSC3E42 Production Partition Conditional Capacity Low Threshold Reached
In this Document
Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]Sun StorageTek Virtual Tape Control Software (VTCS) - Version 6.2 and later Sun StorageTek V2X SVA Disk System - Version All Versions to All Versions [Release All Releases] Sun StorageTek VSM5 System IBM z/OS on System z SymptomsCustomer receives a message on their system, FSC3E41 or FSC3E42 Conditional Capacity Low Threshold Reached. This will be in the form of a SIM message. SLS6659I VTSS VSM5 SIM:0010100000008 FE0629000039E009A1041030EF400003E4105104202F2050FFF CauseFSC 3E41 and FSC 3E42 are reported at the detection of collected free space being only 5% or 2.5%, respectively. SolutionMonitor subsystem with the following VTCS commands to verify whether the DBU is going down or needs attention:
Check for any error messages issued by VTCS or HSC that may indicate a problem with the library or RTDs or FREE MVC counts. Verify from the display outputs that migrations are active and running or if migrations are queued behind any other task. It may be necessary to halt the initiators to prevent jobs from allocating VTDs on the VTSS until the DBU has decreased enough. Attachments This solution has no attachment |
||||||||||||||||
|