![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1635005.1 : VSM - SLS6662E & SLS6625E messages on 9840C Tape Drive on different tapes
In this Document
Created from <SR 3-8684984821> Applies to:Sun StorageTek 9840C Tape Drive - Version Not Applicable and laterSun StorageTek VSM System - Version 4 and later Sun StorageTek VSM5 System Information in this document applies to any platform. SymptomsCustomer see this error message: <SLS6662E RTD RTD15104 PUT IN MAINTENANCE MODE BECAUSE OF ERROR CauseYou find the FSC 9840C error message here (byte 11 and 12): <SLS6625E RTD RTD15104 REPORTED VOLUME FENCED: 104400474F98E22000001707000000000000000000000000CE0E4620093700FF This error message 1707 say: FSC Dictionary Description: SolutionIf the customer has this message on different tapes, replace this Tape Drive. Attachments This solution has no attachment |
||||||||||||||||
|