![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2118259.1 : D/H02.20.03.00 microcode Potential Data Integrity problem if using FASTRECL
In this Document
Created from <SR 3-12336602141> Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]Information in this document applies to any platform. SymptomsThe VSM4, VSM5 or VSM5C may take warm boots. Symptom being documented here was a FSC 8E29 warm boot followed by FSC 8E4A, 8E4B and 3c75 warm boots. Changes The VSM4 or VSM5 is running D02.20.03.00 code and FASTRECL is enabled. The VSM5C is running H02.20.03.00 code and FASTRECL is enabled. CauseThis problem is caused by a microcode fault. SolutionTurn off FASTRECL while the VSM is running D/H02.20.03.00 microcode. This problem will be addressed with the release of D/H02.21.XX.XX code currently scheduled for release in April, 2016. FASTRECL is also known by the following names: Instructions for checking FASTRECL can be found in MOS Doc ID 1456147.1. Attachments This solution has no attachment |
||||||||||||||||||||
|