| Asset ID: |
1-72-1015151.1 |
| Update Date: | 2017-03-10 |
| Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1015151.1
:
VSM - Message SLS5079E mount failed CC=9 RC =146
| Related Items |
- Sun StorageTek VSM System
|
| Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
|
PreviouslyPublishedAs
222977
Applies to:
Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
All Platforms
Symptoms
Message SLS5079E received for VTV mount
SLS5079E MOUNT OF vvvvvv ON dddd - FAILED (rc) - CC=9 RC=146
ECAM error CC=9 RC=146 in the SLS5079E message indicates 'No logical paths established'.
Cause
Possible causes are:
1. VTCS has the address defined in the CONFIG but it is not in the HCD.
2. The affected host does not have any paths to the VTSS that it is sending the ECAM message to.
Solution
1. Define VTCS address in HCD
2. Establish paths to VTSS
Previously Published As
STKKB67794
Attachments