![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1619684.1 : FSC3BBB warm boots, 613-08, 813-04 or A13-10 Abends via VTD0 of VSM
In this Document
Created from <SR 3-8483253151> Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]Information in this document applies to any platform. SymptomsSymptoms vary based on multiple factors. Known symptoms at this time are:
These errors are seen on only the first (low order) VTD (Virtual Tape Drive) within the VSM. Example: If the VSM VTD address range is 400 to 43F then this problem will only manifest on VTD address 400. ChangesRecent upgrade to D02.17.15.00 or H02.17.15.00 microcode. CauseThere is a microcode fault within the code levels noted above (D/H02/17/15/00) that causes a problem in handling FSF (Fowward Space File) operations. This problem results in VTV (Virtual Tape Volume) positioning errors which in turn can lead to any of the symptoms noted above.
SolutionThe work-around for this problem is to vary the first (low order) VTD within the subsystem offline. The fix for this problem will be included in D/H02.18 microcode. D/H02.18 code is expected to be released within the first calendar quarter of 2014. Attachments This solution has no attachment |
||||||||||||||||||
|