Solution Type  Problem Resolution Sure

Solution  2169430.1 :   VSM - HDA (Disk Drive) Ready LED not lit.  


Related Items
  • Sun StorageTek VSM4 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

Sun StorageTek VSM4 System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 New replacement HDA (Head Disk Assembly or just disk drive) ready LED will not light even though the drive passed diagnostics and the GFR (Guided FRU Replacment) was successful.

Changes

 Failed 73GB HDA has been replaced with a Hitachi HDA replacement - part number 7064916.

Cause

 Replacement disk is a Hitachi 73GB disk drive.  The ready LED on these drives will not light in the VSM4.

Solution

 Ignore the fact that the replacement drive LED will not light.  The drive is otherwise expected to work just fine.