Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1569194.1
Update Date:2013-07-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  1569194.1 :   VSM: T10000 Tape Drive Failed to Initialize New MVC Media Using ALP  


Related Items
  • Sun StorageTek VSM4 System
  •  
  • Sun StorageTek Virtual Tape Control Software (VTCS)
  •  
  • Sun StorageTek VSM5 System
  •  
  • StorageTek Virtual Storage Manager System 6 (VSM6)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7260540131>

Applies to:

Sun StorageTek VSM4 System - Version All Versions and later
Sun StorageTek VSM5 System - Version All Versions and later
StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later
Sun StorageTek Virtual Tape Control Software (VTCS) - Version 6.2 and later
Information in this document applies to any platform.

Symptoms

New T10000 (T10K) media failed to initialize.

The VTSS has the required minimum microcode required to support MVC initialization.

Cause

Cisco MDS-9513 switch,  FICON Tape Acceleration (FTA)

Solution

Workaround: Turn off FTA on CISCO switch to initialize blank MVC.  Turn on FTA for data migration performance.

Contact Cisco for details regarding the firmware required to resolve this issue.

BugDB 16856227 filed for CISCO FICON Tape Acceleration (FTA) problem,  this will be the final solution using new CISCO FW.