Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2083456.1
Update Date:2015-12-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2083456.1 :   Potential FSC3BBB warmboots after upgrading from D02.15.xx.00 code if the VSM4 has Escon host connections  


Related Items
  • Sun StorageTek VSM4 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-11554467201>

Applies to:

Sun StorageTek VSM4 System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 Potential FSC3BBB warmboots after upgrading from D02.15 code if the VSM4 has Escon host channels

Changes

 Microcode was upgraded from D02.15.xx.00 to a higher level of microcode

Cause

 If the customer is writing 256K blocks but is using "Standard VTV page (32K)" setting in VTCS/ELS (applicable versions 6.2, 7.0, 7.1, 7.2, 7.3), this potentially will induce the FSC3BBB warmboots on the higher levels of microcode

Solution

 Change the VTCS/ELS (applicable versions 6.2, 7.0, 7.1, 7.2, 7.3) setting to "Large VTV Page (62K)"

References

<BUG:22063969> - FSC3BBB CK0'S WHEN WRITING 256K BLOCKS WITH 32K PAGE SIZE- ZD2.19.12.00

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.