Asset ID: |
1-72-2083456.1 |
Update Date: | 2015-12-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2083456.1
:
Potential FSC3BBB warmboots after upgrading from D02.15.xx.00 code if the VSM4 has Escon host connections
Related Items |
- Sun StorageTek VSM4 System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
|
In this Document
Created from <SR 3-11554467201>
Applies to:
Sun StorageTek VSM4 System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Potential FSC3BBB warmboots after upgrading from D02.15 code if the VSM4 has Escon host channels
Changes
Microcode was upgraded from D02.15.xx.00 to a higher level of microcode
Cause
If the customer is writing 256K blocks but is using "Standard VTV page (32K)" setting in VTCS/ELS (applicable versions 6.2, 7.0, 7.1, 7.2, 7.3), this potentially will induce the FSC3BBB warmboots on the higher levels of microcode
Solution
Change the VTCS/ELS (applicable versions 6.2, 7.0, 7.1, 7.2, 7.3) setting to "Large VTV Page (62K)"
References
<BUG:22063969> - FSC3BBB CK0'S WHEN WRITING 256K BLOCKS WITH 32K PAGE SIZE- ZD2.19.12.00
Attachments