Asset ID: |
1-72-1363752.1 |
Update Date: | 2018-03-21 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1363752.1
:
VSM - How to identify FRU for FSC7E92 or FSC7E93, Power Supply error
Related Items |
- Sun StorageTek VSM System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
|
VSM/VTSS reported FSC7E92 or FSC7E93 to host in a SLS message or MIM via SDP.
In this Document
Applies to:
Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
Information in this document applies to any platform.
Symptoms
VSM fenced a power supply
Power fault LED is lit
Customer received a SIM message containing FSC7E92 or FSC7E93
If attached to SDP, VSM performed a MIM with FSC7E92 or FSC7E93
Cause
The environmental monitoring task has determined that
the N_INT power supply failure line from the logic card
cage power supply in power zone 0 or 1 is asserted. This
assertion indicates that the power supply is no longer
supplying power to the system.
Solution
Customer: Open a service request in MOS for analyze by Oracle Technical Support.
Please insert the whole SIM message in the description field.
See Doc ID 1452594.1 for SIM message examples.
Two methods to confirm error and generate an ATR to facilitate repair:
METHOD 1
Connect to the VSM and log into the machine.
Navigate to FRU status screen
Examine the status of FRUs CU.1.LPS0 and CU.1.LPS1(card type = LPS2) one should be flagged as fenced.
Make note of the exact FRU location that is fenced and the part number of the FRU.
Create Field Task to have the power supply replaced.
Inform customer that the VSM lost one power supply.
The VSM has a failed power supply however the redundant power supply is functioning and there is no impact to production.
End method 1
METHOD 2
NOTE: IF you do not have access to ZENOBIA use SPLATT to crunch files See KM: 1399676.1
1. Get a full set of base files from the VTSS using standard processes.
2. Place files on zenobia using standard filing conventions.
3. Run the crunch_it all script.
EX: crunch_it all <enter>
4. Review hic.dmp file
EX: less hic.dmp <enter>
5. Review hic.dmp file specifically the PSA section.
You should see a Fencing action against CU.1.LPS0 or LPS1 depending on
which power supply failed.
EX: Found PSA Action has taken place
--------------------------------
11/09/18 15:06:34 PSA 0x7e93 INIT FENCE 0105 27 - CU.1.LPS1
6. Review crnt_fru.lst file to identify the part number of the defective
power supply.
7. Create Field Task to have the power supply replaced.
8. Inform customer that the VSM lost one power supply.
The VSM has a failed power supply however the redundant power supply
is functioning and there is no impact to production.
End method 2
References
<NOTE:1399676.1> - VSM/SVA - Crunching and Viewing Files Using SPLAT
<NOTE:1452594.1> - VSM - Sense byte message examples
Attachments
This solution has no attachment