Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1316184.1
Update Date:2018-01-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1316184.1 :   VSM - Warmboot FSC7596 with 3BC8 in sense bytes 30,31 of SIM message  


Related Items
  • Sun StorageTek VSM System
  •  
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-3443801641>

Applies to:

Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
Sun StorageTek VSM5 System
IBM z/OS on System z

Symptoms

SLS6659I SIM occurs on the z/OS host logs.  This SIM from the VSM includes 7596 in sense bytes 22 and 23, indicating a warmboot occurred and bytes 30 and 31 contain 3BC8. 

Fault Symptom Codes
-----------------------
FSC7596_FI_CHECK_0_WARM_BOOT_COMP_OK
FSC3BC8_DISCONNECTED_TIMEOUT_DUE_TO_UNKNOWN_DEV_STAT

Cause

VSM Microcode
 CR 7015268, Product Family: Sun


Solution

Verify successful recovery from the warmboot and the recording of FSC3BC8 in the VSM logs. Contact VSM technical support to help verify if necessary.




References

<BUG:7015268> - BACKPORT:6856221:FAMILY PACK J:11.5.10:UNIT OF MEASURE IS DISPLAYING IN PORTUGES
<NOTE:1317325.1> - VSM - SLS6659I SIM error with FSC7596
<NOTE:1014781.1> - How to Determine the FSC from the Sense Bytes in Message SLS6659I

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback