![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1316184.1 : VSM - Warmboot FSC7596 with 3BC8 in sense bytes 30,31 of SIM message
In this Document
Created from <SR 3-3443801641> Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]Sun StorageTek VSM5 System IBM z/OS on System z SymptomsSLS6659I SIM occurs on the z/OS host logs. This SIM from the VSM includes 7596 in sense bytes 22 and 23, indicating a warmboot occurred and bytes 30 and 31 contain 3BC8. CauseVSM Microcode SolutionVerify successful recovery from the warmboot and the recording of FSC3BC8 in the VSM logs. Contact VSM technical support to help verify if necessary. References<BUG:7015268> - BACKPORT:6856221:FAMILY PACK J:11.5.10:UNIT OF MEASURE IS DISPLAYING IN PORTUGES<NOTE:1317325.1> - VSM - SLS6659I SIM error with FSC7596 <NOTE:1014781.1> - How to Determine the FSC from the Sense Bytes in Message SLS6659I Attachments This solution has no attachment |
||||||||||||||||||
|